Overview
The Bante322-UK Portable water hardness gauge is a professional Portable device equipped with original UK Sensor for outdoor testing of calcium mg Ion concentration in water quality with a Measurement accuracy of 1% F.S. It supports 5 point button calibrate and 8 optional concentration Measurement units to ensure accurate and reliable Water Hardness Analysis.
Features
1. Professional Portable design, equipped with original British Sensor.
2.2 to 5 point button calibrated to cover low to high concentration range.
3. Choose 8 units of Water Hardness, including German, British, French, mmol/L and mg/L.
4. Automatic temperature compensation function to ensure full scale measurement accuracy.
5. Automatic calibration reminder to help users maintain regularly.
6. Automatic end point locking, stable display Measured value for easy recording.
7. Manual temperature calibrating to improve Temperature Measurement accuracy.
8. Low battery alarm icon to monitor battery status in real time.
9. Automatic power off to optimize battery energy consumption.
10. System menu customization function, including 7 parameters such as the number of calibrated points and Stability standards.
11. One-click reset function to quickly restore factory settings.
12. Expand memory to store up to 500 sets of data.
13. The built-in clock automatically marks the date and time of the data, conforming to GLP specifications.
14. USB Communication interface, convenient data transfer to computer.
15. Multi-mode power supply solution, support battery, Power Adapter and USB port.
Principle
Measurement accuracy is ensured by the built-in Sensor that detects the calcium mg Ion concentration in water samples, combined with automatic temperature compensation and calibrating mechanisms. The user can select different units for measurement, the meter automatically locks the stable value and stores the data, and supports manual or automatic temperature calibrating to optimize performance.
Applications
Outdoor water quality testing, environment monitoring, industrial water analysis, boiler water treatment, laboratory research
Standards
GLP specification
Steps
1. Turn on the meter power.
2. Select the required Water Hardness Unit.
3. Perform 2 to 5 point button calibrating, using the specified calibrating liquid.
4. Electrode immersion in water sample to begin measurement.
5. Measured value is automatically locked by the meter, and data can be browsed or recorded.
6. Use the USB interface to transfer and store data to the computer.
7. Manual calibration of temperature or automatic shutdown as required.
Notice
Periodically calibrated to ensure measurement accuracy.
• Pay attention to the battery level and replace it in time to avoid data loss.
• Use the specified calibrating liquid for calibrating operation.
• Avoid use in extreme temperature environments, affecting accuracy.
• Ensure that the built-in clock is accurate when storing data.
• Follow GLP specification requirements when operating.