$ 393.00Ex works
With four measurement functions, accuracy 0.5% F.S, support 1-5 point calibrating and automatic temperature compensation, can customize 11 paraMeters, built-in 500 data storage and USB interface, suitable for a variety of environments.
Category : Conductivity Meter
Brand : Bante
SKU : NB014733
Service :The delivery and service By NBCLab.Com
The Bante540-S Portable Conductivity Meter is a High Accuracy Portable instrument with four measurement functions: conductivity, TDS, salinity and resistivity. The instrument is calibrated with 1 to 5 point buttons, 11 function parameters can be customized in the built-in system menu, and the measurement accuracy is 0.5% F.S. It is equipped with a large screen backlit LCD display.
1. High Accuracy Portable Design with Large Screen Backlit LCD 2.1 to 5 point button calibrated Conductivity detector standard 3. Optional Electrode constant (K = 0.1/1/10), TDS factor, normalized temperature (20 or 25 ° C), linear and pure water temperature compensation, seawater and practical salinity Measurement mode 4. Automatic temperature compensation ensures accurate measurement of full scale 5. Automatic end point locking function, retain stable Measured value 6. Electrode diagnosis, check Electrode slope value 7. The system menu can customize 11 function parameters 8. One-click reset function automatically restores to factory default settings 9. Extended memory can store 500 sets of measurement data 10. Built-in clock automatically marks the date and time of stored data, conforming to GLP specifications 11. USB Communication interface to send data to computer 12. Multi-mode power supply solution (battery, Power Adapter, USB port)
Conductivity detector Electrode measurement solution conductivity and automatic temperature compensation to ensure measurement accuracy. The system can automatically calculate and display TDS, salinity and resistivity values according to the set Electrode constant, TDS factor and temperature compensation mode. Built-in automatic end point locking function retains stable Measured values.
Water quality monitoring, geological and ecological research, chilled down tower and boiler water, printing industry, swimming pool and spa, agriculture and aquaculture, education and laboratory applications
GLP specification
1. Power on and select Measurement mode 2. Set Electrode constant, TDS factor and other parameters as needed 3. Perform 1 to 5 point calibrate 4. Electrode immersion in the solution to be tested 5. Measured value is stable 6. Read or store measurement data 7. Data can be transferred to the computer through the USB interface
• Please calibrate before use • Select the appropriate Electrode Constant Make sure the temperature compensation is set correctly • Regularly check Electrode status • Pay attention to the battery power and replace it in time • Memory capacity when storing data • Electrode cleaning immediately after use
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.