Overview
The Bante980 is a standard laboratory dissolved oxygen meter, equipped with a large LCD screen, supports 1 or 2 point button calibrating, provides 10 functional parameters to choose from, Measurement accuracy is 0.2mg/L.
Features
1. Standard laboratory dissolved oxygen meter with large backlit LCD screen.
2.1 or 2 point button calibrated, using air saturated water or zero oxygen liquid.
3. Manual salinity and atmospheric pressure compensation to improve instrument Measurement accuracy.
4. Automatic temperature compensation, eliminate measurement deviation at different temperatures.
5. Automatic end point lock, keep stable Measured value for easy browsing or recording.
6. Manual temperature calibrating, improve instrument temperature Measurement accuracy.
7. Optional temperature units and dissolved oxygen concentration units (mg/L or ppm) to adapt to the usage habits of different countries.
8. The system menu can customize 9 function parameters such as the number of calibrated points, Stability standard, Display resolution, Data lock mode, and automatic shutdown mode.
9. One-click reset (Reset) automatically restores the meter to the factory default settings.
10. Extended memory can store up to 500 sets of measurement data.
11. The built-in clock automatically marks the time and date of stored data to comply with GLP specifications.
12. USB Communication interface sends stored data to PC.
Principle
Instrument dissolved Oxygen electrode measurement dissolved oxygen concentration, combined with automatic temperature compensation, manual salinity and atmospheric pressure compensation to improve accuracy, and the use of automatic end point locking function stable Measured value.
Applications
Research and education, environment monitoring and ecological research, water and wastewater treatment, other industrial applications
Standards
GLP specification
Steps
1. Use air saturated water or zero oxygen liquid for 1 or 2 point button calibrating.
2. Set manual salinity and atmospheric pressure compensation as required.
3. The instrument automatically performs temperature compensation and end point locking.
4. Optional temperature unit and dissolved oxygen concentration unit.
5. Customize function parameters through the system menu.
6. One-click reset to restore default settings.
7. Store the data and send it to the computer via the USB interface.
Notice
• Make sure the calibrating fluid is correctly selected before use.
• Regularly check Electrode status and filler fluid.
• Avoid operating in extreme temperature or pressure environments.
• Data storage with built-in clock accuracy.
• Clean and maintain Electrode after use.