With 6 measurement functions, support 1-5 point calibrating and automatic recognition of standard solution, built-in 12 customizable paraMeters, equipped with large screen backlight display, extended memory can store 500 sets of data and comply with GLP specifications.
Category : Water Quality Tester
Brand : Bante
SKU : NB014827
Service :The delivery and service By NBCLab.Com
The Bante902-UK Multi-Parameter Water Quality Analyzer is a precision laboratory instrument with six measurements of pH, Oxidation-reduction potential, conductivity, TDS, salinity and resistivity. Equipped with a large-screen backlit LCD display, the built-in system menu supports customization of 12 functional parameters for accurate water quality analysis of various liquid samples.
1. Multi-Parameter integrated design, integrated pH, ORP, conductivity, TDS, salinity and resistivity measurement functions 2.1-5 point intelligent calibrating system, automatic identification of standard buffer and Conductivity detector 3. Support multiple calibrated standard selection (USA/NIST/DIN) and custom calibrated 4. Automatic temperature compensation, Electrode slope display and Electrode diagnostic function 5. Can store 500 sets of data and support USB data transmission, in line with GLP specifications 6. System menu can customize 12 parameters such as calibrated point, Stability standard, automatic shutdown, etc
The instrument detects ionic activity, oxygen-reduction potential and conductive characteristics in water samples by connecting different types of Electrode (pH Electrode, ORP Electrode, Conductivity detector Electrode). The built-in microprocessor Counter electrode signal is digitalized, combined with the temperature sensor data, automatically compensates for the temperature effect through preset algorithms, and finally displays accurate measurement results on the LCD screen.
Laboratory water quality analysis, environment monitoring, drinking water testing, industrial process control, sewage treatment, aquaculture, scientific research and education
GLP specification
1. Select the appropriate Electrode according to the Measurement parameters and connect the instrument 2. Turn on the power and select the desired Measurement mode 3. Use standard liquid for 1-5 point calibrating 4. Electrode immersion in the sample to be tested 5. Record the Measured value after waiting for the reading to stabilize 6. Storage data can be exported via USB interface
• Measurement accuracy must be calibrated before use • Electrode should be cleaned and maintained in time after use • Avoid using the instrument in extreme temperature environments • Electrode status is checked regularly and replaced in time according to the slope prompts • The calibrating liquid should be stored according to the regulations to avoid pollution and deterioration • Ensure a stable USB connection during data transmission
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.