Quasi-dual beam of light dynamic feedback proportional recording photometry system, wavelength range of 190~ 1100nm, scanning speed up to 3500nm/min, with automatic establishment of standard Linear dispersion and a variety of map processing functions.
Category : Spectrophotometer
Brand : laspec
SKU : NB017111
Service :The delivery and service By NBCLab.Com
The Alpha-1860 quasi-dual beam of light scanning UV-Visible Spectrophotometer is designed by LASPEC for the needs of various fields such as organic chemistry, biochemistry, pharmaceutical analysis, food inspection, environment protection, life science, etc. The instrument uses new microcomputer technology and electronic control system to optimize the traditional optical path and structural design, while expanding new functions, ensuring accuracy, stability and durability.
1. Durable and reliable: Key components (deuterium lamp, tungsten lamp, Holographic grating, Detector) are imported parts, Optical inspection mirror coated with SiO2 protective film, full sealing monochromator structure. 2. High stability: using quasi-double beam of light dynamic feedback proportional recording metering system. 3. High automation: with instrument self-diagnosis and correction recovery functions. 4. Functional improvement: support photometric measurement, quantitative analysis, qualitative analysis, kinetic analysis, DNA/RNA and protein testing and other functions. 5. Convenient operation: Built-in micro thermal printer, socket-type deuterium lamp and tungsten lamp replacement without Optical inspection and debugging, equipped with automatic light-seeking positioning system. 6. Extensible: Optional dedicated PC counter-control workstation with USB data interface or PC analyst software with GMP function.
Alpha-1860 uses a quasi-dual beam of light dynamic feedback proportional recording photometry system. Its Optical inspection system is a self-aligning optical path, using 1200 lines/mm laser holographic Diffraction grating for spectroscopy. After the light emitted by the Illuminant is split, one part irradiates the sample, and the other part is used as a reference. Absorbance or light transmitance of the sample at a specific wavelength is measured by dynamic feedback proportional recording, so as to realize qualitative and quantitative analysis.
Organic chemistry, biochemistry, pharmaceutical analysis, food inspection, environment protection, life sciences
No specific compliance criteria were mentioned in the data.
1. Turn it on and perform instrument self-test. 2. Select the Operating Mode (such as photometric measurement, quantitative analysis, etc.) according to the test requirements. 3. Set or call the corresponding test parameters (such as wavelength, scanning speed, etc.). 4. Perform automatic zeroing (100% T and 0% T). 5. Put in the sample and start the measurement. 6. Print data and graphs directly through the built-in micro thermal printer, or perform data processing through the optional PC software.
• Use socket deuterium and tungsten lamps when changing lamps, no need for Optical inspection and debugging. • The instrument is equipped with an automatic light-seeking positioning system for easy debugging and maintenance. • Please ensure that the instrument is running stably before use, and can be checked using the self-diagnostic function. • According to the test requirements, the calibration methods such as single wavelength, dual wavelength or three-point method can be flexibly selected. • Optional dedicated PC software to enhance data processing capabilities.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.