Please contact customer service
Dual beam of light dynamic feedback proportional recording Metering system, Light spectrum bandwidth 2nm, wavelength range 190~ 1100nm, with light source debugging-free function and high automation self-diagnosis, support a variety of analysis modes.
Category : Spectrophotometer
Brand : laspec
SKU : NB017112
Service :The delivery and service By NBCLab.Com
The Alpha-1900 dual beam of light scanning UV-Visible Spectrophotometer is designed by LASPEC for the needs of organic chemistry, biochemistry, drug analysis, food inspection, environment protection, life sciences and other fields. The instrument uses new microcomputer technology and electronic control system to optimize the traditional optical path and structure design, while expanding new functions, ensuring the accuracy, stability and durability of the instrument.
1. Stable and reliable quality: Key components (deuterium lamp, tungsten lamp, Holographic grating, Detector) are imported parts, Optical inspection mirror coated with SiO2 protective film, full sealing monochromator structure. 2. Rugged and durable: 20 mm thick base to ensure that the Optical inspection system can withstand transportation vibration. 3. Stable measurement: Double beam of light dynamic feedback proportional recording metering system to ensure Baseline stability. 4. High automation: Equipped with instrument self-diagnosis and calibration recovery functions to ensure stable operation and accurate data. 5. Functional perfection: adjustable bandwidth to adapt to different sample and test requirements. 6. Various functions: support photometric measurement, quantitative analysis, qualitative analysis, kinetic analysis, DNA/RNA and protein testing. 7. Efficient and convenient: scanning speed up to 3500nm/min, light source free debugging (socket deuterium lamp and tungsten lamp, automatic light-seeking positioning). 8. Extensible: Dedicated PC anti-control workstation or GMP function PC analyst software that can be used with USB interface.
Alpha-1900 adopts dual beam of light and CT optical path design. The instrument emits a continuous Light spectrum through Illuminant (tungsten halogen lamp and deuterium lamp), and forms monochromatic light after Holographic grating. The monochromatic light is recorded by the dynamic feedback ratio of the dual beam of light metering system. One beam passes through the sample, and the other beam is used as a reference. The Detector (imported silicon photodiode) receives and compares the light intensity signals of the two beams, thereby calculating the Absorbance, transmittance and other parameters of the sample, and performs data processing and analysis through the microcomputer system.
Organic chemistry, biochemistry, pharmaceutical analysis, food inspection, environment protection, life sciences
The data did not mention specific compliance criteria.
1. Turn it on and warm up. 2. According to the test requirements, set the test mode through the instrument or software (such as photometric measurement, quantitative analysis, qualitative scanning, kinetic analysis, etc.). 3. Place the reference solution with the sample solution. 4. Perform automatic adjustment of 100% T and 0% T (zero adjustment). 5. Start measurement, instrument automatic scanning or fixed-point detection. 6. View and process data (e.g. scaling, smoothing, filtering, peak and valley detection, etc.) through a monitor or connected PC workstation. 7. After the test is completed, turn off the instrument properly.
• The instrument should be placed on a stable, non-strong vibration surface. Make sure the instrument is fully preheated before use to ensure stability. • When replacing deuterium or tungsten lamps, use its socket design and automatic light-seeking positioning system, without complex Optical inspection and debugging. • Keep Optical inspection parts clean and avoid touching the mirror directly with your hands. • Light spectrum bandwidth is reasonably selected according to sample characteristics and test accuracy requirements. • When performing quantitative analysis, it is necessary to correctly establish and select the standard Linear dispersion fitting method. When connecting PC software, make sure to use dedicated interfaces and software. • Be careful when handling, although the instrument base is strong, it should still avoid violent collisions.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.