Category : Spectrophotometer
Brand : laspec
SKU : NB017115
Service :The delivery and service By NBCLab.Com
Alpha-1900Plus dual beam of light smart scanning UV-Visible Spectrophotometer is designed by LASPEC for the needs of organic chemistry, biochemistry, pharmaceutical analysis, food inspection, environment protection, life science and other fields. The instrument uses new microcomputer technology and electronic control system to optimize the traditional optical path design and structural design, while expanding new functions, ensuring accuracy, Stability and durability.
1. Adopt 9.7-inch tablet display (2G memory, 32G storage space), data transmission through Bluetooth, and remote reliable and stable control within 3 meters. 2. Support Chinese and English interface. 3. Support Wi-Fi/Bluetooth data access, Email on-site data transmission. 4. Support Google cloud printing and area network printing. 5. Convenient data format conversion and storage (e.g. PDF, Excel, etc.). 6. It is convenient to access backup data through the USB port U disk. 7. PC connection software (optional) can implement audit trail function. 8. Support online upgrades. 9. Key components (deuterium lamp, tungsten lamp, Holographic grating, Detector, etc.) are imported. Optical inspection mirror is coated with SiO2 protective film, and the fully sealed monochromator structure ensures stability, reliability and long life. 10.20Mm thick base, to ensure that the Optical inspection system can withstand strong vibration. 11. Dual beams of light dynamic feedback proportional recording metering system to ensure Baseline Stability. 12. Highly automated instrument self-diagnosis and calibration recovery functions ensure stable operation and accurate test data. 13. Select adjustable Bandwidth to expand the application range for different samples and test requirements to ensure test accuracy. 14. The lamp source is free of debugging function, the socket type deuterium lamp and tungsten lamp are free of Optical inspection and debugging when changing the lamp, and the automatic light-seeking positioning system makes debugging and maintenance simple and convenient.
The Alpha-1900Plus uses a dual beam of light and a CT optical path system. After the light emitted by the light source is split by the monochromator, it is divided into two beams, one beam passes through the sample and the other beam is used as a reference. The dynamic feedback proportional recording system of the dual beam of light compares the light intensities of the two beams in real time to accurately measure the Absorbance or Transmittance of the sample at a specific wavelength.
Organic chemistry, biochemistry, pharmaceutical analysis, food inspection, environment protection, life sciences
The data did not mention specific compliance criteria.
1. Photometric measurement: measurement of the sample's Absorbance and transmittance at the specified wavelength; multi-wavelength fixed-point testing can simultaneously determine multiple wavelengths. 2. Quantitative analysis: Automatically establish standard Linear dispersion, can choose first-order and first-order zero-crossing linear regression, second-order and third-order Linear dispersion fitting, can choose single wavelength correction, dual wavelength correction, three-point method; can store standard Linear dispersion for later call. 3. Light spectrum scanning, scanning speed up to 3500nm/min, adjustable speed; map processing methods include scaling, smoothing, filtering, peak and valley detection. 4. Kinetic analysis: Perform enzyme kinetic reaction rate calculation; choose scaling, smoothing, filtering, peak and valley detection, derivation and other map processing methods. 5. DNA/RNA, protein testing: Use the built-in special calculation formula to directly obtain the final result.
* Optical inspection parts of the instrument are coated with protective film and should avoid contact or scratching. * The instrument is designed with a thick base to resist vibration, but care must be taken to avoid severe impacts during transportation and use. When using the adjustable Bandwidth function, the appropriate Bandwidth should be selected according to different samples and test requirements to ensure the accuracy of the test. * When replacing deuterium or tungsten lamps, there is no need for complex Optical inspection and debugging due to the socket design and automatic light-seeking positioning system. When controlling remotely through a tablet, please be careful to stay within an effective communication distance (approximately 3 meters) to ensure stable data transmission. When storing and transferring data, you can use various methods such as Wi-Fi, Bluetooth, Email, USB flash drive, etc., and pay attention to the conversion and backup of data formats. * For audit tracking function, PC connection software is required. * The instrument supports online upgrades, please update it in a timely manner to ensure complete functionality.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.