Please contact customer service
Using thermal conductivity detection principle, built-in pump suction measurement and integrated Filter, sampling distance is greater than 10 Meters, can directly detect negative or positive pressure gas. Equipped with 2.31 inch high definition color screen, support a variety of data storage and alarm modes.
Category : Gas Detector
Brand : GaoPin
SKU : NB017457
Service :The delivery and service By NBCLab.Com
The GAOPIN NGP40-N2 portable multi-function nitrogen detector is an instrument for rapid detection of nitrogen gas concentration and environment temperature and humidity (optional). It uses the principle of thermal conductivity detection and is equipped with a high definition color screen. When the measurement value exceeds the limit, it will emit sound and light vibration alarm. The instrument is suitable for detecting gas concentration in pipes, confined spaces, atmospheric environments, and high concentration single gas purity with nitrogen or oxygen background. It can detect more than 500 gas types.
1. Detect nitrogen gas concentration. 2. Built-in pump suction measurement, integrated water vapor, dust Filter, can be used for high humidity, high dust environment; sampling distance is greater than 10 meters, can directly detect negative pressure or positive pressure -0.5~ 2 kg of gas. 3.2.31 inch high definition color screen, display real-time concentration, alarm, time, temperature, humidity, storage and other information. 4. Large-capacity data storage function (standard 100,000), support real-time, timing or only store alarm data, support local view, delete and USB upload. 5. Optional high temperature sampling and cooling filtrate handle or pretreatment system can detect flue gas at a temperature of 400 degrees. 6. Three display modes can be switched: simultaneously display four gas concentrations, large font cyclic display single channel concentration, real-time Linear dispersion display. 7. Linear dispersion graphically shows the trend of gas concentration. 8. Data recovery function, optional recovery. 9. Display MAX Maximum, MIN Minimum, Average. 10. Standard USB charging interface, with charging protection function, supports USB power supply operation. 11. Using 4500mA large capacity rechargeable polymer battery, long battery life. 12. Optional High Accuracy temperature and humidity measurement function. 13. Supports real-time or timed detection, and the pump can be turned off to extend the startup time. 14. Various alarm methods: sound and light, vibration, visual alarm; alarm types include concentration, undervoltage, fault alarm. 15. Multiple alarm modes: low alarm, high alarm, interval alarm, and weighted average alarm. 16. Misoperation identification function can avoid calibrating misoperation. 17. Zero automatic tracking, long-term use is not affected by zero drift. 18. The target point is calibrated in multiple stages to ensure the Linearity and accuracy of the measurement. 19. Chinese and English interfaces are optional. 20. Operating temperature range: -40~ + 70 ℃, support temperature compensation. 21. Logging function, including calibrate, repair, fault log, and provide Sensor life expiration and next calibrate time reminder. 22. Meet the requirements of intrinsically safe circuit design, anti-static, anti-electromagnetic interference. 23. Protection Rating up to IP65, waterproof splash, dustproof, explosion-proof, shockproof.
The NGP40-N2 portable multi-function nitrogen detector adopts the principle of thermal conductivity detection for gas concentration measurement. The instrument has a built-in pump suction sampling system, which sucks the gas to be measured through a special gas circuit design. After integrated water vapor and dust Filter treatment, the gas comes into contact with the Sensor. The Sensor converts the gas concentration signal into an electrical signal, which is processed by professional circuit design and mature kernel algorithm, and finally displays the real-time concentration value on the screen. When the concentration exceeds the preset limit, the instrument will trigger an audiovisual vibration alarm.
Pipeline gas concentration detection, confined space Gas detection, atmospheric environment Gas detection, gas leakage detection, high concentration single gas purity detection with nitrogen or oxygen background
Exia Ⅱ CT6
1. Power on: Long press the power button to start the instrument. 2. Mode selection: Select real-time detection or timing detection mode as needed. 3. Sampling: The built-in pump of the instrument automatically starts sampling to ensure that the sampling port is aligned with the gas environment to be measured. 4. Reading: Read real-time gas concentration, temperature and humidity information on the 2.31-inch high definition color screen. 5. Data storage: The instrument automatically saves data according to the settings (real-time, timing, or alarm storage). 6. Alarm processing: When the concentration exceeds the standard to trigger the alarm, take corresponding measures according to the sound, light and vibration prompts. 7. Data viewing and management: Data can be viewed and deleted locally through the instrument menu, or uploaded to the computer through the USB interface. 8. Charging: Charge the instrument through the standard USB interface, with charging protection function.
• Optional high temperature sampling cooling filtrate handle or pretreatment system, can detect high temperature flue gas, higher temperature needs to be customized. • The instrument has a built-in Filter, which allows it to be used in high humidity or high dust environments, but it is still necessary to avoid physical damage to the instrument due to extreme conditions. • When performing concentration calibrating, please note that the instrument has the function of misoperation identification, and the wrong operation will be prevented. • Please pay attention to the Sensor life expiration reminder and the next concentration calibrating time reminder in the instrument log, and maintain it in time. • Instrument Protection Rating is IP65, waterproof splash and dust, but non-diving equipment, do not immerse in water. • The instrument is intrinsically safe explosion-proof equipment, and the explosion-proof mark is Exia II CT6. Please use it in the specified dangerous place. • When not detected for a long time, the pump suction function can be turned off to save power and prolong the startup time of the instrument. • Avoid use in strong electromagnetic interference environments to ensure measurement accuracy. • Please use a matching or compliant USB charging device when charging.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.