Please contact customer service
Using fluorine-free environmental protection refrigerant and imported Compressor, low energy consumption and high efficiency. Temperature range -20~ 130 ℃, humidity control range 30~ 95% RH, with independent temperature limit alarm and multi-stage programmable control, simplify the complex test process.
Category : Temperature Humidity Chamber
Brand : YiHeng
SKU : NB017910
Service :The delivery and service By NBCLab.Com
YIHENG high and low temperature (alternating) Damping heat testing chamber integrates the company's many years of successful experience in box design, in line with the humanized design concept, starting from the actual needs of customers, meeting customer requirements in details, and providing high-quality products. Fluorine-free design, equipped with multi-functional multi-stage programmable temperature and humidity controller, precise temperature and humidity control.
1. Humanized design: fluorine-free and environmentally friendly design; wet and dry ball type or electric kiln type multi-functional multi-stage programmable temperature and humidity controller, fuzzy PID control, accurate temperature and humidity control fluctuation is small; imported temperature and humidity controller has long life, High Accuracy LCD display, easy to operate; there is a test hole on the left side of the box for easy operation; built-in sink can be pulled out to add water. 2. Quality assurance: brand Compressor and circulating fan, uniform temperature distribution; environmentally friendly refrigerant (R134a) with high efficiency and low energy consumption; unique air duct circulation system to ensure uniform temperature and humidity; imported 304 mirror stainless steel liner, excessive four corners and half arcs, free loading and unloading of shelf brackets for easy cleaning; multi-stage programmable control to achieve automatic operation. 3. Safety functions: independent temperature limit alarm system, over-limit automatic interruption and sound and light alarm; high temperature, low temperature and over-temperature alarm; Compressor overheating, overcurrent, overload protection, fan overheating protection, water shortage protection, etc. 4. Convenient data processing (optional): can be connected to the printer or 485 communication interface, with USB data transfer interface (SD disk), with computer display and print temperature, humidity and time Linear dispersion, to provide data storage and playback guarantee. 5. Programmable touch screen controller (BPHJS series standard): color LCD touch control screen, menu-type operation interface intuitive and easy to operate; Chinese and English operation interface optional, screen display real-time temperature and humidity running Linear dispersion; preset 100 groups of 1000 steps 999 cycles program; with screen lock function; P.I.D automatic calculation function makes the control more accurate and stable; with RS-232 or RS-485 communication interface, you can design programs, monitor the test process and execute the switch machine on the computer; professional control software can realize simultaneous monitoring and control of 9 devices; real-time analysis and storage of data on the computer, forming Excel or Word documents for easy printing.
The test chamber drives the refrigeration and air circulation system through the brand Compressor and circulating fan, and uses the environmentally friendly refrigerant (R134a) to achieve efficient cooling. The environment in the box is detected by the dry and wet bulb or electric kiln temperature and humidity Sensor, and the heating, humidification, refrigeration and dehumidification modules are precisely adjusted by the fuzzy PID controller. Combined with the unique air duct circulation system, the temperature and humidity of the studio are uniform and stable. Multi-stage programmable control realizes the automatic operation of the complex temperature and humidity alternating test process.
Reliability test of electronic products, material weathering resistance test, environmental adaptability assessment of automotive parts, aerospace parts test, Stability study of chemical products, storage conditions simulation of pharmaceutical products, R & D institution environment simulation experiment
The data did not mention specific compliance criteria
1. Place the device in a suitable location and connect it to a power supply (AC220V 50Hz). 2. Add water to the equipment through the built-in pull-out sink. 3. Operate the temperature and humidity controller through the keyboard or touch screen to set the required test temperature, humidity, and program steps. 4. Place the sample on the shelf and into the studio. 5. Start the equipment and the test starts running. 6. During the test, measurement or operation can be carried out through the test hole on the side of the box. 7. After the test, remove the sample and turn off the power of the device. 8. (Optional/standard function) Data can be exported through USB interface, or data analytics and report generation can be carried out through professional software on the computer.
• Before the equipment runs, ensure that the water supply is normal to avoid triggering water shortage protection. • Do not operate beyond the device's limited Temperature range (-20~ 130 ℃, 30~ 95% RH). • Pay attention to the equipment alarm prompt (such as overheating, Compressor overheating, etc.), and deal with it in time. • When cleaning the box, the shelf bracket can be removed for easy cleaning. • When using the touchscreen controller, the screen lock function can be enabled to prevent misoperation. • The equipment is heavy (Net weight 213Kg), so pay attention to safety during handling and installation. • To maintain Temperature Uniformity ( +/- 2 ° C) and Flexibility (+/- 0.5 ° C), do not overcrowd the sample.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.