Overview
BOZHEN KRG-450B light chamber is a fluorine-free design equipment, using brand-name Compressor and circulating fan, equipped with a large LCD screen, with convenient operation, high efficiency and low energy consumption. It can effectively save energy, has a long service life, and adopts a silent design to reduce working noise. Compared with traditional cryogenic equipment, the cooling time can be reduced by more than 40%.
Features
1. The box adopts high-quality steel plate spraying process, the liner is made of mirror stainless steel, and the Shelf spacing in the box can be adjusted.
2. Adopt a digital display screen for intuitive display, making it easy to observe and operate.
3. Equipped with brand Compressor and circulating motor, with a unique air duct structure to ensure uniform temperature and humidity in the working room.
4. Equipped with advanced fuzzy PD intelligent temperature and humidity controller, it can control temperature and humidity with small fluctuations, and has a timing function of 0-999 minutes.
5. Temperature can be set to different day and night modes depending on the availability of light.
6. Equipped with an independent temperature limit alarm system, the temperature exceeds the limit and is automatically interrupted to ensure the safety of the experiment.
7. Optional RS485 interface is available to connect to the computer for monitoring the experimental process.
Principle
The lighting chamber carries out cooling and air circulation through the brand Compressor and circulating fan system, and cooperates with the unique internal air duct design to ensure a uniform studio environment. The fuzzy PD intelligent temperature and humidity controller precisely adjusts the climate conditions in the box, and can automatically switch the day and night temperature mode according to the preset light cycle to simulate different environment climates.
Applications
Microbial tissue cell fostering, seed germination, seedling experiment, plant cultivation, insect and small animal feeding
Steps
1. Place the device in a suitable working environment (temperature 5~ 30 ° C) and connect the AC 220V 50Hz power supply.
2. Perform parameter settings through the large LCD screen, including temperature (10~ 50 ° C/4~ 50 ° C in with/without light mode), humidity (50~ 90% RH), Illumrination degree (0~ 20000LX, six-level adjustable) and timing time (0~ 9999 minutes).
3. Adjust the Shelf spacing in the box as needed and place the sample.
4. Start the device, and the real-time status can be observed through the display screen during operation.
5. After the experiment is completed or the timing is completed, turn off the power of the device.
Notice
Equipment should be placed in accordance with the requirements of the Ambient Temperature (5~ 30 ℃) for use.
• Power frequency is AC 220V 50Hz and input power is 1650W.
Before running, please confirm that the parameters are set correctly, especially the temperature limit, to prevent the independent alarm system from being triggered.
• Continuous Operating Time is recommended to not exceed 180 hours to ensure stable operation of the equipment.
• Optional RS485 interface and computer connection function are optional, please confirm the configuration if you want to use it.
When performing cleaning or maintenance, please disconnect the power supply first.