Please contact customer service
Measurement range 0~ 1250μm, resolution up to 0.1μm. Support a variety of Probe and temperature compensation, with Data storage, limit alarm and wireless communication functions, V-groove design for pipe measurement.
Category : Coating Thickness Gauge
Brand : KODIN
SKU : NB020648
Service :The delivery and service By NBCLab.Com
MC-3000S Coating thickness gauge is a precision measuring instrument launched by KODIN, which can quickly and non-destructive measurement of coating and platings thickness. The instrument can be used in both laboratories and engineering sites. By using different probes, it can meet a variety of measurement needs and is widely used in manufacturing, metal processing, chemical industry, commodity inspection and other testing fields.
1. Using magnetic and eddy current thickness measurement methods, nondestructive measurement of nonmagnetic coating thickness on magnetic metal substrate and nonconductive coating thickness on nonmagnetic metal substrate. 6 types of probes (F0.5, F1.2, F3, F5, F10, N1.2) can be used. 3. With temperature compensation function, equipped with Kedian's new "phase-locked loop" technology. 4. With screen flip function, you can manually select flip to display measurement data. 5. Measurement speed can choose two modes of single measurement and continuous measurement. 6. Three methods can be used to calibrate the instrument, and the basic calibrating method can be used to correct the systematic error of the probe. 7. With storage function, it can store more than 10,000 measurement points. 8. With deletion function, suspicious data or all stored data in the storage group can be deleted. 9. The limit can be set, and the Measured value outside the limit can be automatically alarmed. 10. With printing function, you can connect a Bluetooth printer to print measurement data. 11. With data connection function (Bluetooth 2.0), it can communicate wirelessly with computers and printers. 12. With power undervoltage indication function. 13. There is a beep prompt during the operation. 14. There are two shutdown methods: manual shutdown and automatic shutdown. 15. The V-groove structure facilitates the measurement of coatings on the outer surface of pipes of various sizes. 16. The large flat bottom Probe structure makes the measurement more stable and Repeatability is higher. 17. Professionally designed anti-skid pad with the anti-skid texture on the back of the case, so that the operation is not easy to fatigue.
MC-3000S Coating thickness gauge is based on magnetic induction and eddy current. For the nonmagnetic coating on magnetic metal substrate, the magnetic method is used for measurement; for the nonconductive coating on nonmagnetic metal substrate, the eddy current method is used for nondestructive thickness measurement.
Manufacturing, metal processing, chemical industry, commodity inspection and other testing fields
GB/T 4956─1985、GB/T 4957─1985、JB/T 8393─1996、JJG 889─95、JJG 818─93
1. Select the appropriate probe according to the measurement substrate (magnetic or nonmagnetic) and the type of coating and install it. 2. Turn it on and select Measurement mode (such as lite mode, monitoring mode, statistical mode, MIN Minimum capture) according to the screen prompts. 3. Calibrate the instrument (one of three calibration methods can be used, and the basic calibrating method can be used to correct the probe system error if necessary). 4. Smooth and vertical contact of the probe with the coating surface to be tested for measurement. 5. Read and record measurement data, the instrument can automatically store data. 6. You can connect a Bluetooth printer to print data as needed, or transfer data to a computer through Bluetooth. 7. After the measurement is completed, you can choose to shut down manually or wait for automatic shutdown.
* Please select the appropriate probe according to different applications (e.g. base material, coating type, curvature, etc.). * When measuring, ensure that the probe is in smooth and vertical contact with the measured surface to obtain accurate readings. * The instrument has a temperature compensation function, but the performance may be affected in extreme temperatures (other than -10 ° C to + 40 ° C) or high Humidity (> 90% RH) environments. * When calibrating, use a standard sheet similar to the substrate and coating of the sample to be tested to ensure measurement accuracy. When the instrument indicates that the power supply is under-voltage, please replace the two AA batteries in time. * The instrument has a data deletion function, please operate with caution to avoid deleting important measurement data by mistake. * When using V-groove to measure curved surfaces such as pipes, please ensure that the probe fits well with the curved surface. * Probe is split, please pay attention to protection when using and storing to avoid falling or impact. Instruments comply with a number of national standards, but users still need to confirm their suitability according to specific industry or application requirements.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.