Overview
EVERFINE MUG-2 Miniature Single Angle Glossiness Meter is mainly used for the measurement of material and surface Gloss in lame plating, plastic, printing, metal, Pottery and porcelain, building materials, leather, paints and other industries.
Features
1) High measurement accuracy: The measurement accuracy is better than 1.5%, which is at the international professional level.
2) High stability: High performance LED Illuminant, Light spectrum matching high, life of 60,000 times.
3) Automatic calibration and zero correction function: built-in standard calibrating device, can be corrected and zero at any time, so that the test is more accurate.
4) Automatic determination function: The upper and lower limits can be designed to automatically determine whether the test results are qualified or not. Users can set and call different judgment criteria at will.
5) Large LCD screen display, friendly user interface design, can display gloss value intuitively.
6) The instrument automatically shuts down to save power.
Principle
The Glossiness Meter irradiates the measured surface at a 60 ° angle through the built-in LED Illuminant, receives reflected light, converts the light signal into an electrical signal through the photoelectric Sensor, calculates the gloss value by the internal processor, and displays it on the LCD screen.
Applications
Lame plating, plastic, printing, metal, Pottery and porcelain, building materials, leather, paints and other industries
Standards
DIN 67530、ISO 2813、ASTM D 523、JIS Z8741、BS 3900 Part D5、JJG696
Steps
1) Turn it on.
2) Perform automatic correction or zero correction as required.
3) Select the measurement mode (basic measurement, sample measurement, statistical measurement or continuous measurement mode).
4) Align and fit the instrument measurement window to the measured surface.
5) Take measurements and read gloss values.
6) The upper and lower limits can be set for automatic determination.
Data can be exported via USB, Bluetooth, or SD card.
Notice
• Make sure the instrument is properly calibrated before measurement.
• When measuring, the instrument measurement window (light spot size 9mm × 15mm) should be completely fitted to the tested surface.
• Select the appropriate sample according to the measurement range (0.1~ 1000 GU).
• Note that the resolution of the instrument varies in different ranges (0 to 100:0.1; 100 to 1000:1).
• The instrument has an automatic shutdown function to save power.
• 100 sets of stored data can be exported via SD card.
• The power supply method is battery, please pay attention to the power.
• Please refer to relevant compliance standards when operating to ensure measurement compliance.