Overview
Kenton KH-55A digital display electric air blowing dryer is a device using microcomputer intelligent PID control technology, with temperature control, timing and over-temperature alarm functions. Suitable for routine experiments and tests, cost-effective, for drying, heat treatment, heating use in various industries.
Features
1. Using microcomputer intelligent PID control technology, the system has temperature control, timing, over-temperature alarm functions;
2. The external hot air circulation system is composed of low-noise fans and air ducts, and the reasonable air duct and circulation system make the temperature in the working room stable;
3. Cold rolled steel plate with good electrostatic spray treatment, the overall design is beautiful and novel, and has a large viewing window;
4. The liner is divided into two types of mirror stainless steel and galvanized steel plate, and the semi-arc four corners are easy to clean;
5. The shelf spacing and shelf number in the working room can be adjusted to facilitate access to samples of different specifications;
6. Using high temperature silicone as the sealing edge of the door, high temperature heating tube as the heating element to ensure safety and longer service life;
7. Ergonomic fastening handle, easy to operate, and ensure sealing.
Principle
The drying oven precisely adjusts the temperature through microcomputer intelligent PID control technology, and uses the external hot air circulation system composed of low-noise fans and air ducts to achieve uniform and stable distribution of temperature in the working room. The high-temperature heating tube provides heat as a heating element, and the high-temperature resistant silicone sealing door edge ensures that heat is not lost.
Applications
Drying, heat treatment, heating in various industries, biology, agriculture, scientific research and other departments
Steps
1. Put the sample into the working room, adjust the shelf spacing and quantity to adapt to the sample specifications;
2. Close the box door and ensure that the sealing door is tight;
3. Set the required temperature and timing time.
4. Start the equipment and monitor the running status.
5. Remove the sample after the timing is over.
Notice
• Flammable, explosive and volatile items are strictly prohibited from being heated and dried in the box;
• For heating high-value materials, it is recommended to install an independent temperature limiter and set the maximum temperature limit;
• Not suitable for volatile, flammable, explosive and other items to avoid explosion;
• It is recommended to use for routine experiments and tests, and it is recommended to install an independent temperature limiting controller for more expensive samples.