$ 830.00Ex works
The cavity preheating technology is used to ensure uniform temperature distribution, and with an adjustable air circulation system, the Temperature Uniformity reaches +/- 0.5 ° C, supports remote monitoring and multi-device connection, and is easy to clean and maintain.
Category : Incubator
Brand : HengLi
SKU : NB021248
Service :The delivery and service By NBCLab.Com
HENGLI PX-40 electric incubator is suitable for microbial foster and other industries, and is the required equipment for biological, agricultural and scientific research experiments. The ALLHEAT ™ cavity preheating technology meets different temperature requirements, provides a constant temperature environment, and cooperates with Pro-Insulation ™ thermal insulation technology to ensure the smooth progress of sample experiments and foster. The product has passed the European Union CE safety certification, complies with the Australian AS/NZS3350 standard, and enjoys a 2-year mass warranty period.
1. ALLHEAT ™ cavity preheating technology: heating elements are evenly distributed around the liner, through heat transfer and forced fan convection to ensure uniform temperature distribution, low energy consumption, heat energy is not easy to lose. 2. ALLFLOW ™ air circulation system: forced convection ensures quick recovery of temperature after opening the door, adjustable wind speed, with fan switch function. 3. ALLSENS ™ microcomputer PID control technology: integrated LCD large-screen liquid crystal display, Chinese and English optional, adaptive PID control precise temperature, user password control, RS485 interface can be connected to multiple devices for real-time monitoring. 4. Pro-Insulation ™ insulation technology: liner and shell complete isolation design, high density imported insulation materials, silicone door seal and isolation hinge to ensure sealing. 5. Sophisticated imported temperature sensing components: Industrial grade PT100 temperature transducer Response is fast, self-heating effect is small. 6. Ergonomic structural design: circular arc design, integration of outer door and LCD panel, adjustable spacing of movable mesh Shelf, double door design (incubator series). 7. Easy to clean: the liner is designed with minimal splicing, and the multi-layer shelf can be extracted for easy cleaning. 8. Easy maintenance: LCD micro-electric control appliance diagnostic function, electrical control components are separated for easy maintenance. 9. Safe and effective protection: multiple over-temperature protection sound and light alarm, automatic double over-temperature safety protection, electronic components have passed UL certification, and over-temperature protection meets German DIN 12880 Class 3.1 standard.
ALLHEAT ™ cavity preheating technology uses heating elements to evenly distribute around the liner, preheating the inner wall of the cavity, and then through heat transfer and forced fan convection to accurately reach and maintain the set temperature at each point in the cavity to ensure uniform temperature distribution. ALLFLOW ™ air circulation system adopts forced convection to ensure rapid temperature recovery after opening the door, and cooperates with the cooling fan to achieve a stable foster environment. ALLSENS ™ microcomputer PID control technology precisely controls the temperature through the adaptive PID program to prevent temperature overshoot and keep the temperature in the cavity constant.
Microbial fostering, biological experiment, agricultural experiment, scientific research experiment
European Union CE safety certification, Australian AS/NZS3350 standard, German DIN 12880 Class 3.1 standard
1. Connect the power supply to AC 220V/50Hz. 2. Select Chinese and English display through the LCD control panel, and set parameters such as temperature (RT + 5~ 65 ° C) and time (0~ 99 hours or 0~ 9999 minutes). 3. Adjust the wind speed and fan switch as required. 4. Use the user password to control the start-up operation, and monitor the temperature, wind speed, running time, and other states. 5. Optional microcomputer software remote control, real-time monitoring of multiple devices connected through RS485 interface. 6. After the operation is completed, the device will automatically stop or be stopped manually.
• Ambient Temperature should be kept at 10~ 30 ℃, humidity < 70% RH. • Power frequency check before use meets AC 220V/50Hz requirements. • Avoid operating equipment in hot or humid environments. • Regularly clean liners and shelves to ensure equipment hygiene. • During maintenance, pay attention to the electrical control components located at the back of the box and require professional operation. • When the over-temperature protection function is triggered, deal with the sound and light alarm in time. • Equipment gross weight 43kg (including wooden frame), be careful to avoid damage when handling.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.