$ 977.00Ex works
Adopting ALLHEAT cavity preheating technology, Temperature Uniformity +/- 0.5 ℃, equipped with ALLFLOW air circulation system, the temperature recovers quickly after opening the door, and supports remote monitoring and multiple over-temperature protection.
Category : Incubator
Brand : HengLi
SKU : NB021249
Service :The delivery and service By NBCLab.Com
HENGLI PX-70 electric thermal incubator is suitable for microbial foster and other industries, and is the required equipment for biological, agricultural and scientific research experiments. It adopts ALLHEAT ™ cavity preheating technology to meet different temperature requirements and provide a constant temperature environment, and cooperates with Pro-Insulation ™ thermal insulation technology to ensure the smooth progress of sample experiments and foster. The product has passed the European Union CE safety certification, complies with the Australian AS/NZS3350 standard, and provides IQ, OQ, PQ and various verification services in Chinese/English, and enjoys a 2-year mass warranty period.
1. ALLHEAT ™ cavity preheating technology, uniform distribution of heating elements to ensure uniform temperature distribution, low energy consumption, heat energy is not easy to lose; 2. ALLFLOW ™ air circulation system, forced convection to ensure rapid recovery of temperature after opening the door, adjustable wind speed, with fan switch function; 3. ALLSENS ™ microcomputer PID control technology, integrated LCD LCD display, Chinese and English display, adaptive PID control, precise temperature control, user password control, RS485 interface can connect multiple devices; 4. Pro-Insulation ™ isolation insulation technology, liner and shell complete isolation design, high density insulation materials, silicone door seals and isolation hinges to ensure sealing; 5. Original imported industrial grade PT100 temperature transducer, Response is fast, Self-heating effect is small; 6. Ergonomic structure design, Arc Appearance, adjustable movable mesh Shelf, double door design (incubator series), easy to observe and keep warm; 7. Easy to clean, liner minimum splicing design, activities can be extracted shelf, easy to clean; 8. Easy maintenance, LCD control appliance diagnostic function, electrical control components are installed separately; 9. Safe and effective protection, multiple over-temperature protection, sound and light alarm, UL certification for electronic components, in line with German DIN 12880 Class 3.1 standard.
The ALLHEAT ™ cavity preheating technology distributes the heating elements evenly around the inner tank, preheats the inner wall of the inner cavity, and then through heat transfer and forced fan convection, ensures that the temperature at each point in the cavity accurately reaches and remains at the set value to achieve uniform temperature distribution. The ALLFLOW ™ air circulation system adopts forced convection to ensure the rapid recovery of temperature after opening the door, and cooperates with the cooling fan to maintain continuous temperature stability. The ALLSENS ™ microcomputer PID control technology precisely controls the temperature through the adaptive PID program to prevent temperature overshoot and keep the temperature in the cavity constant.
Microbial fostering, biology, agriculture, scientific research experiment
European Union CE safety certification, Australian AS/NZS3350 standard, German DIN 12880 Class 3.1 standard
1. Connect the power supply and ensure that the voltage is AC 220V/50Hz. 2. Open the device and select the Chinese or English interface through the LCD liquid crystal display; 3. Set temperature parameters, Temperature range is RT + 5~ 65 ℃, temperature resolution 0.1 ℃; 4. Set the Timer Range, optional 0~ 99 hours or 0~ 9999 minutes; 5. Adjust the wind speed and fan switch as required. 6. Place the sample on the movable mesh Shelf and adjust the Shelf spacing; 7. Start operation and monitor temperature, wind speed, running time, etc. 8. Use the RS485 interface to connect multiple devices for remote monitoring (optional); 9. After the operation, shut down the equipment and perform cleaning and maintenance.
- Ensure that the Ambient Temperature is 10~ 30 ℃ and the humidity is below 70% RH; - Power frequency check meets AC 220V/50Hz requirements before use; - Avoid operating equipment in hot or humid environments; - Regular cleaning of liners and shelves to maintain equipment hygiene; - Pay attention to the over-temperature protection alarm during operation and deal with abnormal situations in a timely manner. Disconnect the power supply during maintenance to ensure safety. - Use only original parts to avoid unauthorized modifications. - Follow the user manual for setting and operation to prevent misoperation. - During the warranty period, if you have any questions, please contact after-sales services.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.