$ 4085.00Ex works
With five-level adjustable light and +/- 1 ℃ Temperature Fluctuation, using ALLCOLD equilibrate refrigeration and ALLFLOW air circulation system, support multi-stage programming control and remote monitoring to ensure a stable and efficient experimental environment.
Category : Incubator
Brand : HengLi
SKU : NB021269
Service :The delivery and service By NBCLab.Com
The HENGLI LC-400 light chamber is a professional equipment widely used in biological tissue, cell foster, seed germination, plant planting, small animal and insect feeding applications. It can simulate daytime and evening Illumrination degree changes and climate conditions, supports multi-stage step programming control, and is equipped with ALLCOLD ™ refrigeration technology, ALLFLOW ™ air circulation system and Pro-Bright ™ professional lighting system to ensure constant temperature and uniform lighting.
1. ALLCOLD ™ equilibrate refrigeration technology, equipped with automatic defrosting, multi-layer safety protection and environmentally friendly refrigerant, energy saving and efficient. 2. ALLFLOW ™ air circulation system to ensure rapid temperature recovery and stability, and adjustable wind speed. 3. ALLSENS ™ microcomputer PID control technology, supports Chinese and English display, adaptive PID control, user password and remote monitoring. 4. Double-decked isolation and thermal insulation technology to reduce energy consumption, and the inner isolation door is designed to maintain the same temperature in the inner cavity. 5. Ergonomic structural design, including circular arc Appearance, movable mesh Shelf and double door, improve the operation comfort. 6. Easy to clean and maintain, liner is easy to clean, controller has diagnostic function, electrical components are installed separately. 7. Multiple safety protections, including over-temperature protection, sound and light alarms, and UL-certified electronic components. 8. Pro-Bright ™ professional lighting system, simulates natural light, Illumrination degree grading is adjustable, and cooperates with ALLIGENT ™ humidification system (limited to Artificial climate box) for climate simulation.
The light chamber precisely adjusts the temperature through the ALLSENS ™ microcomputer PID control technology to prevent temperature overshoot and keep the cavity uniform and constant. The ALLCOLD ™ cooling technology uses an equilibrate solution and a fast heat pump to defrost to ensure continuous operation. ALLFLOW ™ forced convection of the air circulation system to ensure temperature stability and rapid recovery. Pro-Bright ™ lighting system simulates daytime and night light, compensates for the heat of light through the control system, maintains constant temperature, and uses mirror stainless steel reflection to achieve uniform lighting.
Biological tissue fostering, cell fostering, seed germination, plant planting, small animal feeding, insect feeding
National standard, Australian AS3100, US FDA, EN, ICH, cGMP/ICH/380/95/Q1A and Q1B, European Union CE safety certification, German DIN 12880 Class 3.1 standard
Connect the power supply and ensure that the voltage is AC 220V/50Hz. 2. Open the device and select the Chinese or English interface through the LCD display. 3. Set the temperature range (10~ 60 ℃ without light or 10~ 65 ℃ with light), Illumrination degree (0~ 15000LX) and Timer Range (0~ 99 hours or 0~ 9999 minutes). 4. Adjust the wind speed and light level as needed (five levels adjustable). 5. Place the sample on the movable mesh Shelf, adjust the interval and quantity. 6. Start operation and monitor temperature, wind speed and operating status. 7. Use the RS485 interface to connect multiple devices (up to 16) for remote monitoring (optional software). 8. After the operation, shut down the equipment and perform cleaning and maintenance.
• Ensure that the Ambient Temperature is between 10 and 30 ° C and the humidity is below 70% RH. • Power frequency check before use to avoid overload. • Regularly clean the liner to reduce splicing design for easy maintenance. • Pay attention to the over-temperature protection function, and deal with it in time if there is a sound and light alarm. • Follow the user password control during operation to prevent misoperation. • Pay attention to the ventilation hole to dissipate heat during the use of the lighting system to avoid overheating. • During maintenance, the electrical control components are located at the back of the box to ensure power-off operation. • The equipment enjoys a 2-year mass warranty period. If you have any questions, please contact after-sales services.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.