Overview
LICHEN LC-XF-200S Solid Density Meter is a direct reading density measuring instrument using the principle of Archimedes water displacement method. It can directly measure and read the average weight in air, average weight in water, density value and volume of solid, granular, thin film, floating, powder and other samples.
Features
1. Directly read the density and volume of any solid block, particle, floating body with a density > 1 or < 1.
2. With temperature compensation setting and solution compensation setting functions, the operation is more user-friendly and more in line with the needs of on-site operations.
3. Integrated injection molding of density measurement table, easy and fast installation, longer service life.
4. The integrated forming corrosion-resistant large sink design is adopted to reduce the error caused by the buoyancy of the hanging rail line and facilitate the testing of larger block objects.
5. With density upper and lower limit functions, it can determine whether the specific gravity of the object to be tested is qualified or not, and a buzzer device is provided.
6. The whole system adopts German HBM Sensor.
7. Built-in battery, with Draft Shield, more suitable for field testing.
8. Standard RS232 external interface.
9. Large-screen LCD display.
10. Optional liquid accessories can test the density and concentration of the liquid.
Principle
The Density Meter works on Archimedes' principle of water displacement. By measuring the weight of the sample in air and completely submerged in a liquid of known density (usually water), the volume of the sample is calculated using the principle of buoyancy, and its density value is directly derived.
Applications
Rubber, Plastic, Wire and cable, Food, Composites, Cosmetics, Shoe Material, Glass, Precious Metal Hardware Recycling
Standards
GB/T533、ISO2781、ASTMD297-93、DIN53479、ASTMD792、D618、D891、ISO1183、GB/T1033、ASTM D792-00、JISK6530
Steps
1. Place the sample on the measurement table and measure its weight in the air.
2. Immerse the sample completely in water (or a liquid of known density) and measure its weight in water.
3. The instrument automatically calculates and directly displays the density value and volume of the sample according to the Archimedes principle.
Notice
• Please ensure that the instrument is placed horizontally before use.
• Ensure that the sample is completely submerged and free of bubbles during testing.
• According to the test requirements, set the temperature compensation and solution compensation parameters correctly.
• Regularly clean the measurement sink and railing to prevent pollution from affecting the Measurement accuracy.
• Do not exceed the Capacity of the instrument (200g).
• The built-in battery needs to be charged regularly to ensure on-site use.
• The liquid density and concentration test can be carried out after the optional liquid accessories.