LICHEN LC-XF-120SD Solid Density Meter is a direct reading density measuring instrument based on the principle of Archimedes substitution method in water. It can directly measure and read the average weight in air, average weight in water, density value and volume of solid, granular, thin film, floating, powder and other samples. It is suitable for quality control and material analysis in various industries.
Features
1. Directly read the density and volume of any solid block, particle, floating body with a density > 1 or < 1.
2. With temperature compensation setting and solution compensation setting functions, the operation is more user-friendly and meets the needs of on-site operations.
3. Integrated injection molding of density measurement table, easy and fast installation, long service life.
4. The integrated forming corrosion-resistant large sink design is adopted to reduce the error caused by the buoyancy of the hanging rail line and facilitate the testing of larger block objects.
5. With density upper and lower limit functions, it can determine whether the specific gravity of the object to be tested is qualified or not, and a buzzer device is provided.
6. The whole system adopts German HBM Sensor.
7. Built-in battery, with Draft Shield, more suitable for field testing.
8. Standard RS232 external interface.
9. Large-screen LCD display.
10. After the liquid accessories are selected, the density and concentration of the liquid can be tested.
Principle
The Density Meter uses the principle of water displacement by Archimedes. By measuring the weight of the sample in air and the weight of the sample completely immersed in a liquid of known density (usually water), the volume of the sample is calculated using the principle of buoyancy, and then its density value is directly obtained.
Applications
Rubber, Plastic, Wire and cable, Food, Composites, Cosmetics, Shoe Material, Glass, Precious Metal Hardware Recycling
Standards
GB/T533、ISO2781、ASTMD297-93、DIN53479、ASTMD792、D618、D891、ISO1183、GB/T1033、ASTM D792-00、JISK6530
Steps
1. Place the sample on the measurement table and measure its weight in the air.
2. The sample is completely immersed in the liquid of the integrally formed large water tank, and its weight in the water is measured.
3. The instrument automatically calculates and directly displays the density value and volume of the sample according to the measured two sets of weight data.
Notice
• Please ensure that the instrument is placed horizontally before use.
• According to the test requirements, set the temperature compensation and solution compensation parameters correctly.
• When submerging the sample, make sure that there are no bubbles attached to the surface of the sample and it is completely submerged.
When testing larger bulk objects, be aware of the capacity limitations of large sinks.
• Regularly calibrate the instrument to ensure Measurement accuracy.
• After the liquid accessories are selected, the liquid density and concentration can be tested.