Overview
Air bath thermostatic Shaker (also known as air thermostatic Shaker) is a temperature-controlled thermostatic air box and Shaker combination of biochemical instruments, plants, organisms, microorganisms, genetics, viruses, environmental protection, medicine and other scientific research, education and production departments for precision foster preparatory indispensable laboratory equipment. It has the characteristics of easy use and simple operation, so it has been greatly used in chemical industry, food and scientific research institutions, and is a standing laboratory instrument.
Features
1. Temperature, Oscillation Frequency Dual Digital Display, Intelligent Temperature Control Instrument Temperature Control Accurate.
2. All stainless steel liner, standard stainless steel multi-function spring clip, stepless speed regulation.
3. 304 stainless steel water retaining plate is standard around, which effectively prevents water from splashing out during oscillation.
4. Supporting circuit board, thyristor control, high-power transformer.
5. Super-large motor to ensure the sustainability of oscillation power.
Principle
The instrument combines the functions of the thermostatic air box and the Shaker. The air temperature in the box is precisely controlled by the intelligent temperature control system, and the swirling or reciprocating oscillation of the sample is realized by the motor drive, providing a thermostatic and continuous oscillation foster environment for biological and chemical experiments.
Applications
Plant research, biological research, microbial fostering, genetics experiments, virus research, environmental monitoring, medical research, chemical industry experiments, food testing, scientific research institutions and education
Steps
1. Place the instrument on a stable bench.
2. Turn on the power supply and turn on the power switch.
3. Set the required Temperature, Oscillation Frequency and Timing Time (or set to Normally Open Mode) through the Control Panel.
4. Secure the sample container to be fostered in the working chamber with the standard stainless steel spring clamp.
5. After confirming that the parameters are set correctly, start the oscillation and heating functions and start running.
6. After running, turn off the power and remove the sample.
Notice
• The instrument should be placed in a smooth, well-ventilated environment.
• Power supply voltage meets requirements before use.
When loading samples, they should be evenly distributed to ensure smooth operation.
• During operation, do not turn on and off frequently or move the instrument violently.
• When cleaning the instrument, please disconnect the power supply first and wipe it with a soft cloth to avoid liquid entering the electrical part.
• If not used for a long time, the power supply should be cut off and the instrument should be cleaned and stored in a drying place.