Overview
CS-10B high-purity water machine adopts RO membrane reverse osmosis and anion and cation exchange technologies, selects imported materials, and prepares high-purity water based on the principle of ion selective permeability. It can effectively remove organic matter, inorganic anion and cation, colloids, bacteria and other impurities in water, and the effluent water quality meets the national laboratory water standard (GB6682-92), and finally reaches Reagent grade high-purity water without interference background.
Features
1. Using imported ion filtrating membrane and high voltage, silent pure water pump, the operation mass is more reliable, and the water quality is more widely applicable.
2. With system flushing function: before each time the machine is turned on to make water, it will automatically flush for 18 seconds, and then the system will start making water.
3. With system protection function: when the water pressure is too low or there is no water, the equipment will automatically shut down, and the equipment will automatically turn on when the water source comes.
4. High output, low energy consumption, power saving: water output 20L/h, Power consumption is only 50W.
5. Adopting a professional water treatment process, the high-purity water outlet ratio is approximately 40%, and the water consumption is minimal.
6. No need for electric heating, no scaling phenomenon, no need to clean.
7. No heat loss, the effluent does not need to be cooled down at room temperature, and can be directly used for experiments.
8. Easy to operate, easy to maintain, and low operating costs.
9. With a two-stage RO pre-desalination system (high salinity water quality optional).
10. With water quality and water quantity upgrade functions.
Principle
The high-purity water machine adopts RO membrane reverse osmosis and anion and cation exchange technologies, and is based on the principle of selective permeability of ions to prepare high-purity water. Through multi-stage filtrating and treatment, various impurities in water are effectively removed.
Steps
Make sure that the inlet water source, water pressure (≥ 0.1 Mpa) and water temperature (5~ 40 ° C) meet the requirements, and connect the 220V/50HZ power supply.
2. After power on, the device will automatically perform an 18-second system flushing process.
3. After the system is flushed, the equipment automatically begins to produce high-purity water.
Notice
• The equipment has an automatic protection function, which will automatically shut down when the water pressure is too low or there is no water. It will automatically turn on after the water source is restored, without manual intervention.
The equipment does not require electric heating, so there is no scaling phenomenon and no cleaning operation is required.
• The equipment has no heat loss and produces high-purity water at room temperature, which can be used directly for experiments without chilling down.