Overview
DGF-4S electric air blowing dryer uses the air in the working room after electric heating, and is forced to circulate by the fan to make the work area and the heated object carry out uniform heat exchange, so as to achieve the purpose of thermostatic fostering or drying. The product has the characteristics of novel shape, accurate temperature control, stable performance and convenient operation. It is suitable for laboratories of industrial and mining enterprises, scientific research institutes and other units for drying, baking, wax dissolving and heat treatment.
Features
1. Adopting PID temperature control technology, the LED digital tube clearly displays the set temperature and current temperature.
2. With timing, over-temperature alarm, temperature deviation trimming and temperature control self-tuning functions.
3. Adopt double fan and double air duct circulation and electric heating tube heating on both sides to ensure uniform temperature.
4. Vertical double door structure, large internal space, adjustable Shelf height to meet different needs.
5. Equipped with multiple large windows with thickened Glass, it is convenient to observe the situation in the studio.
6. The shell is made of cold-rolled steel and electrostatic spray treatment, which is resistant to corrosion and aging.
Principle
The drying oven heats the air in the working room through an electric heating element, and then uses a fan to force the air to perform a swirl/spin cycle. This forced convection method makes the hot air flow evenly in the working area and exchange heat fully and evenly with the heated object, so as to achieve a fast and uniform thermostatic drying or fostering effect.
Applications
Laboratories, drying, baking, wax dissolving, heat treatment of industrial and mining enterprises, scientific research institutes, Universities & colleges
Steps
1. Connect the AC380V power supply.
2. Set the required temperature and timing time through the control panel.
3. Put the items to be disposed of on the shelf in the studio.
4. Close the box door and start the device to work.
5. During the work process, the internal situation can be observed through a large window.
6. After reaching the set time or completion, turn off the power of the device and remove the item.
Notice
Equipment should be used in a well-ventilated environment.
• Ambient Temperature is recommended between 5 ° C and 40 ° C.
• The items placed should not block the air duct to ensure uniform temperature.
• Pay attention to the over-temperature alarm function to avoid excessive temperature.
• When cleaning and maintaining, please disconnect the power supply first.