Overview
LICHEN LHS-800C biochemistry cultivating box is a thermostatic device with a two-way temperature regulation system for refrigeration and heating, with controllable temperature. It is an important test equipment for scientific research institutions, Universities & colleges, production units or departmental laboratories in biology, genetic engineering, institutions, environment protection, agriculture, forestry and animal husbandry, etc. It is widely used in low temperature thermostatic test, foster test, environmental test, etc. It is suitable for factory breeding, Food processing, and sample preservation under 5-50 ° C.
Features
1. Intelligent Program Control system, with timing, alarm, over-temperature protection and other functions.
2. The original imported refrigeration Compressor is used to achieve fluorine-free refrigeration and is equipped with a fan circulation system.
3. The front door adopts magnetic tape sealing, excellent sealing performance, easy to open.
4. With Compressor overheating protection, instrument failure protection and other multiple safety measures to ensure the normal operation of the experiment.
5. The studio is made of stainless steel, with a four-corner arc transition, which is beautiful and easy to clean.
Principle
The biochemistry cultivating box achieves two-way temperature regulation through an intelligent program Control system combined with the fluorine-free refrigeration and heating system of the original imported refrigeration Compressor. Internal fan circulation ensures uniform temperature in the box to meet the precise temperature control requirements in the range of 5-50 ° C.
Applications
Biological, genetic engineering, institutions, environment protection, agriculture, forestry, animal husbandry and other industries Research institutions, Universities & colleges, production units or departments Laboratories, factory breeding, Food processing, sample preservation
Steps
1. Place the equipment in a stable, well-ventilated position.
2. Connect the power supply and turn on the power switch of the device.
3. Set the required temperature (range 5-50 ° C) and timing time (range 0-9999 minutes) through the LCD display.
4. Place the samples to be fostered or preserved on the shelf (standard 2, load-bearing 15KG).
5. Close the front door and make sure the magnetic strip is well sealed.
6. When the equipment starts to work, the Intelligent Control system will automatically maintain the set temperature and cycle.
7. After the experiment, turn off the power of the device and remove the sample.
Notice
• Please ensure that the equipment is placed in a smooth and well-ventilated environment for use.
• Do not exceed the equipment specified Temperature range (5-50 ℃) and shelf load (15KG) for operation.
• When the equipment is running, do not open the door frequently, so as not to affect the internal temperature Stability and sealing performance.
• When cleaning the studio, use soft fabric and avoid corrosion cleaners.
• In case of Compressor overheating, instrument failure and other alarms, please stop using it immediately and contact a professional to check.
• Regularly check the sealing of the door sealing magnetic strip, if damaged, please replace it in time.