Overview
The SAFETAK GC90S-O2 Single-point Wall-Mounted Gas Monitor Alarm is a device for detecting oxygen concentration in non-explosion-proof environments. It is powered directly from a 220V AC power supply, has a corrosion-resistant die-cast aluminum housing, Protection Rating to IP66, and can be connected to a Miscellaneous control linkage via an optional relay signal output.
Features
1. Ultra-high Protection Rating: IP66 protection, good waterproof and dustproof performance, die-cast aluminum shell corrosion resistance, with strong electromagnetic Shielding performance.
2. High product mass: Sensor adopts international good brand, high detection accuracy and short reaction time.
3. High-intensity, diverse alarm system: with up to 120dB acoustic alarm and 360 ° high-intensity light alarm, it is clearly visible at a distance.
4. Two display modes are available: LCD and LED.
5. Humanized design: Maintain the menu password lock to prevent misoperation; optional relay signal output can be connected to other control linkage devices.
Principle
The alarm continuously detects oxygen through the Sensor of electrochemistry principle, and displays the detected gas concentration information through the display screen (LCD). When the gas concentration reaches the preset low alarm point (19% vol) or high alarm point (23% vol), the device will trigger the sound and light alarm and output the corresponding signal.
Applications
Petroleum, petrochemical, metallurgical and other industrial sites of non-explosion-proof places, gas stations, boiler rooms, laboratories, Food processing and other sites and office environments.
Standards
In line with the national standard of GB12358-2006 "General technical requirements for working environment Gas detection alarm instrument", and obtained the type approval certificate of Measurement instrument.
Steps
1. Install the equipment at the target monitoring location.
2. Connect the 220V AC power supply to power the device.
3. After the equipment is powered on, it enters the working state and starts to continuously detect the oxygen concentration in the environment.
4. Observe gas concentration readings in real time through the display screen (LCD).
5. If you need to connect an external control device, you can configure the optional 4-20mA signal output or two-stage relay signal switch output.
6. Set and calibrate equipment parameters through the password-protected maintenance menu.
Notice
* This product is only suitable for use in non-explosion-proof environments.
* Please ensure that the working Ambient Temperature is between -20~ 50 ℃, Humidity ≤ 95% RH and no condensation.
* Please ensure that the Operating Pressure is within the range of 86~ 106kPa.
* The power requirements are 220VAC +/- 15%.
* Enter the password when performing maintenance operations to prevent misoperation.
Please adhere to relevant safety regulations when installing and using.