Overview
FARUI FR-1240-250A Constant Temperature and Humidity Incubator can be used for bacterial fostering, breeding, fermentation and other thermostatic experiments and fostering in scientific research and industrial production departments such as industrial production, biochemistry and agricultural science. The equipment adopts large LCD display microcomputer intelligent adjustment technology for temperature control, with automatic display function of measuring temperature and setting temperature at the same time, and has PID adjustment, thermostatic timing and self-tuning functions, high temperature control accuracy, strong anti-interference ability, and easy operation.
Features
1. Cold rolled steel plate is used on the outer box, electrostatic spraying process is used on the surface, the liner is stainless steel, the insulation layer is formed by polyester foam, and the light-transmitting window is double-decked Hollow Glass to ensure the insulation performance in the box.
2. Adopt "zero-crossing" touchless switch circuit technology to realize pulse width adjustment heating and cooling, the temperature control fluctuation range is less than 0.5 ° C, and the internal unevenness is about 1.0 ° C.
3. It is controlled by a microprocessor and has functions such as monitoring, temperature control, and protection.
4, brushed stainless steel liner, easier to clean the studio, the shelf can be arbitrarily set and height adjustment.
5. The back of the box is provided with an exhaust hole, and the bottom is provided with a ventilation hole. The gases evaporated by the experimental items can be discharged from the back.
Principle
The principle of air circulation is adopted to make the temperature distribution in the box more uniform and the temperature rise more stable. The heating principle adopts the principle of air circulation and combines the intelligent adjustment technology of microcomputer to control the temperature.
Applications
Industrial production, biochemistry, agricultural science, bacterial fostering, breeding, fermentation, thermostatic experiments
Steps
1. Conditions of use: Ambient Temperature 10-30 ℃, no strong corrosive gas, well ventilated, relative humidity below 85%, Power Supply 220V +/- 10%, 50HZ capacity not less than 1KW, good grounding wire.
2. How to use: Before use, place the ultrasonic Nebulizer next to the machine, add water to the ultrasonic Nebulizer, connect the gasification pipe, and plug the ultrasonic Nebulizer power cord into the three-wire socket behind the right side of the box.
3. Stop humidifying when the machine is heated.
Notice
1. When using the humidifier, you should pay attention to adding water in time, and add water once every 1-2 days according to the humidity requirements to prevent damage. When adding water, remove the humidifier power plug, remove the humidifier water storage tank, turn it up and unscrew the water sealing port counterclockwise. After adding water, tighten the sealing port, put it on the humidifier, and press the humidifier power supply.
2. After the equipment lands, if the ground is uneven, it should be leveled.
3. The general movement of the equipment should be parallel, and the inclination in either direction should be less than 45 degrees.
4. During normal operation of this equipment, the placement of the contents in the box should not affect the air circulation to ensure uniform temperature in the box.
5, the wall liner and equipment surface should be wiped frequently to keep clean.
6. If it is not used for a long time, the power cord should be removed to prevent the equipment from being charged and injuring people. It should also be operated regularly (usually in the first quarter) for 2-3 days according to the conditions of use to remove moisture from the electrical components and avoid damage to the relevant devices.