Overview
The HZLB LGZD-580A cryogenic light chamber is a smart foster device that uses microcomputer program control to precisely adjust temperature and light, simulate day and night temperature changes or provide a stable Illuminant environment, suitable for plant growth research. The device has a volume of 580L and uses Air-Cooled refrigeration technology. Temperature range, Temperature control accuracy is high, and continuous cycle working ability.
Features
1. Microcomputer program control temperature, Illumrination degree, can simulate day and night temperature changes or provide stable Illuminant.
2. 30-stage programs can be set, each lasting 1-99 hours, to meet the requirements of plant growth parameters at different stages.
3. Adopt brand Compressor and environmentally friendly refrigerant (R134a) to ensure long-term stable, efficient and energy-saving operation of the equipment.
4. Mirror stainless steel liner, four corners and a half arc transition, Shelf bracket can be freely loaded and unloaded, easy to clean the box.
5. Equipped with an independent temperature limit alarm system, overheating is automatically interrupted to ensure the safety of the experiment.
6. Optional CO2 inlet and imported infrared CO2 Sensor controller to promote plant growth.
Principle
The incubator regulates the Compressor refrigeration system, heating system and lighting system through a microcomputer program Control system to achieve accurate setting and cycling of temperature and light in the box. Its Air-Cooled technology ensures uniform and stable temperature, and an independent temperature limit alarm system monitors temperature safety in real time.
Applications
Plant growth research, seed germination test, biological fostering, environment simulation experiment
Standards
Domestic patented products
Steps
1. Place the device in a place that meets the requirements of the working Ambient Temperature (+ 5~ 30 ° C), and connect the AC220V 50Hz power supply.
2. Through the microcomputer control panel, set the required temperature program (a total of 30 segments can be set) and lighting program.
3. Install or adjust the Shelf bracket in the box as needed to place the experimental samples.
4. Start the device, and the device will run automatically according to the set program, simulating temperature and light changes.
5. During the experiment, the operating status can be monitored through the control panel.
6. After the experiment, turn off the equipment, disconnect the power supply, and perform cleaning and maintenance in the box.
Notice
Equipment should be placed in a well-ventilated workplace with Ambient Temperature + 5~ 30 ° C.
Make sure to use an AC220V 50Hz power supply and ensure good grounding.
• When the equipment is running, do not switch the box door frequently, so as not to affect the temperature control accuracy.
• Do not use corrosion cleaners when cleaning liners.
• If a CO2 system is selected, follow the relevant instructions to properly connect and use the CO2 gas source and controller.
The equipment is equipped with an independent temperature limit alarm. Please check the setting parameters and the operating status of the equipment when alarming.
• When not in use for a long time, please disconnect the power supply and clean and protect the equipment.