Overview
The HZLB LGZD-350A cryogenic light chamber is a smart foster device that uses microcomputer program control to accurately simulate day and night temperature changes and provide a stable light environment. It is suitable for research on plant growth, seed germination, etc. The device has a volume of 350L, uses a mirror stainless steel liner, is designed for easy cleaning, and is equipped with a brand-name Compressor to ensure long-term stable operation.
Features
1. Microcomputer program control temperature and Illumrination degree, can simulate day and night temperature changes or provide stable Illuminant.
2. 30-stage programs can be set, each time adjustable from 1 to 99 hours, to meet the parameter requirements of different stages of plant growth.
3. Using brand Compressor and environmentally friendly refrigerant (R134a), efficient operation and low energy consumption.
4. Mirror stainless steel liner, four corners and half arc transition, Shelf bracket can be freely loaded and unloaded, easy to clean in the box.
5. Equipped with an independent temperature limit alarm system, overheating is automatically interrupted to ensure experimental safety.
6. Optional CO2 inlet and imported infrared CO2 controller to promote plant growth.
Principle
The incubator precisely adjusts the Compressor refrigeration system and heating system according to the preset program instructions through the microcomputer Control system to achieve precise control of the temperature in the box. At the same time, the Control system adjusts the built-in Illuminant to achieve programmatic control of light intensity and time, thereby creating a settable temperature and light environment for the samples in the box.
Applications
Plant growth research, seed germination experiments, biological fostering, agricultural research
Standards
Domestic patented products
Steps
1. Place the device in a working environment of + 5~ 30 ° C and connect the AC220V 50Hz power supply.
2. Through the microcomputer control panel, set the required temperature program section (a total of 30 sections can be set) and the running time of each section (1-99 hours).
3. Set the light intensity level (adjustable at three levels) and lighting time program as required.
4. Put the sample to be fostered into the box and place it reasonably.
5. Start the program, the device starts to run according to the set parameters, and enters the Continuous Cycle Operating Mode.
6. During operation, real-time temperature, lighting and other parameters can be observed through the panel.
7. When the experiment is over or needs to be cleaned, stop the machine first, and then load and unload the Shelf bracket for cleaning in the box.
Notice
● Equipment should be placed in Ambient Temperature + 5~ 30 ℃, well ventilated place.
● Rated voltage AC220V 50Hz power supply.
● Before running, please confirm that the program parameters are set correctly, especially the Temperature range (-15~ 50 ℃) and lighting settings.
● Pay attention to the equipment alarm prompt, after the over-temperature protection system starts-up, it needs to be checked and troubleshooted before it can continue to run.
When cleaning the liner, do not use corrosion cleaners to avoid damage to the stainless steel surface.
If a CO2 system is selected, it is necessary to follow the relevant instructions for operation and maintenance.