Overview
The HZLB LGZD-1000B cryogenic light chamber is a smart foster device with a volume of 1000L. It is controlled by a microcomputer program, which can accurately simulate the temperature and light changes during the day and night, providing controllable environmental conditions for plant growth, biological research, etc. The equipment adopts Air-Cooled refrigeration technology, Temperature range, stable operation and continuous operation.
Features
1. Microcomputer program control temperature and Illumrination degree, can simulate day and night temperature changes or provide stable Illuminant.
2. Up to 30 programs can be set, each time adjustable from 1 to 99 hours, to meet the requirements of different growth stages.
3. Adopt brand Compressor and environmentally friendly refrigerant (R134a) to ensure long-term continuous, efficient and low energy consumption operation of the equipment.
4. The liner is made of mirror stainless steel, with four corners and a half arc transition, and the Shelf bracket can be freely loaded and unloaded, which is convenient for cleaning in the box.
5. Equipped with an independent temperature limit alarm system, overheating is automatically interrupted to ensure the safety of the experiment.
6. Optional CO2 inlet and imported infrared CO2 controller to promote plant growth.
Principle
The incubator precisely adjusts the Compressor refrigeration system and heating system according to the preset program instructions through the microcomputer Control system to achieve precise control of the temperature in the box. At the same time, the Control system drives the lighting components to provide light according to the set level and time, simulate the natural light environment or provide the stable Illuminant required for the experiment, thus creating a closed foster space with programmable temperature and light regulation.
Applications
Plant fostering, seed germination, biological research, microbial fostering, tissue fostering
Standards
Domestic patented products
Steps
1. Place the device in a working environment of + 5~ 30 ° C and connect the AC220V 50Hz power supply.
2. Open the box door and install or adjust the Shelf bracket as required.
3. Close the door and set the required temperature, Illumrination degree and program parameters through the microcomputer control panel.
4. After confirming that the parameters are set correctly, start the device and start running.
5. During the experiment, the real-time operation status can be observed through the panel.
6. After the experiment, turn off the power supply of the equipment and perform cleaning and maintenance in the box.
Notice
● Equipment should be placed in a well-ventilated place with Ambient Temperature between + 5 and 30 ° C.
Please use a power supply of the specified specification (AC220V 50Hz) and ensure good grounding.
When setting up the program, please pay attention to the rationality of each running time and parameter setting.
● When the equipment is running, do not switch the box door frequently to avoid affecting the internal environment Stability.
● When cleaning the box, please power off the operation and pay attention to protect the surface of the stainless steel liner.
If the device alarms, check and troubleshoot it immediately to ensure safety before use.
The optional CO2 system needs to be installed and debugged by professionals.