Overview
The HZLB LGZD-1500B cryogenic light chamber is a smart foster device that uses microcomputer program control to accurately simulate day and night temperature changes and provide a stable light environment, suitable for scientific research such as plant growth. The device has a volume of 1500L and uses Air-Cooled refrigeration technology. Temperature range is wide, light intensity is adjustable, and long-term continuous operation is supported.
Features
1. The microcomputer program controls the temperature and Illumrination degree, which can simulate the temperature changes of day and night, and can also choose Illuminant with sufficient and stable growth environment.
2. 30 programs can be set, each with a time range of 1-99 hours, and different segmentation parameters can be set to meet the different parameters of plant growth.
3. Brand Compressor to ensure that the test equipment for a long time continuous operation, refrigerant (R134a), effective, low energy consumption, promote energy saving.
4. Mirror stainless steel liner, four corners and half arc transition, Shelf bracket can be freely loaded and unloaded, easy to clean the box.
5. It is equipped with an independent temperature limit alarm system, which automatically interrupts when the temperature exceeds the limit to ensure the safe operation of the experiment without accidents.
6. Can be added: with CO2 air inlet (to promote plant growth) and CO2 controller (imported infrared CO2 Sensor).
Principle
The incubator uses a microcomputer program Control system to comprehensively control the Compressor refrigeration system, heating system and lighting system to achieve accurate setting and cycling of temperature and light in the box. It uses Air-Cooled technology for temperature control, and can program multiple different temperature and light parameters to simulate the natural environment or specific growth conditions.
Applications
Plant growth research, seed germination test, biological fostering, environment simulation experiment
Standards
Domestic patented products
Steps
1. Place the device in a working environment (temperature + 5~ 30 ° C) that meets the requirements, and connect the AC220V 50Hz power supply.
2. Set the required temperature program through the microcomputer control panel (a total of 30 segments can be set, each segment is 1-99 hours) and lighting parameters (0-12000LX, four-level adjustable).
3. Start the equipment, the Compressor and lighting system start to work, and the equipment enters the continuous cycle operation mode.
4. During the experiment, the Shelf bracket can be loaded and unloaded, or the gas environment in the box can be adjusted by the additional CO2 system.
5. After the experiment, turn off the power supply of the equipment and perform cleaning and maintenance in the box.
Notice
Equipment should be placed in a temperature + 5~ 30 ℃ environment.
Make sure to use an AC220V 50Hz power supply.
The equipment is equipped with an independent temperature limit alarm system, please do not disable it at will to ensure safety.
● When cleaning the liner, remove the Shelf bracket and use a soft cloth to wipe the mirror stainless steel liner.
If you need to promote plant growth, consider adding a CO2 air inlet and controller.
The equipment works in a continuous cycle mode, please ensure a stable power supply.
● When setting parameters, please note that the Temperature Fluctuation is +/- 0.5 ℃~ +/- 1.0 ℃.