Overview
The HZLB LRGD-250A cryogenic light chamber is an intelligent Artificial climate box with a volume of 250L. It uses microcomputer program control to accurately simulate day and night temperature, Humidity and light changes, providing stable environmental conditions for plant growth, seed germination and other research. The equipment uses Air-Cooled refrigeration technology and the liner is made of mirror stainless steel. It is designed for easy cleaning and supports long-term continuous operation.
Features
1. Microcomputer program control Temperature, Humidity, Illumrination degree, can simulate day and night environment changes, or provide stable Illuminant.
2. 30-stage programs can be set, each time adjustable from 1 to 99 hours, to meet the parameter requirements of different stages of plant growth.
3. Adopt brand Compressor and environmentally friendly refrigerant (R134a) to ensure long-term stable, efficient and low energy consumption operation of the equipment.
4. Mirror stainless steel liner, four corners and half arc transition, Shelf bracket can be freely loaded and unloaded, easy to clean in the box.
5. Equipped with an independent temperature limit alarm system, overheating is automatically interrupted to ensure the safety of the experiment.
6. Optional CO2 inlet and imported infrared CO2 controller to promote plant growth.
Principle
The incubator coordinates the work of the refrigeration system, the heating system, the humidification system and the lighting system according to the preset program instructions through the microcomputer Control system. The refrigeration system uses Air-Cooled technology and Compressor to achieve precise control of the temperature in the box; the humidification system controls Humidity; and the lighting system provides adjustable vertical lighting to create a temperature, Humidity and lighting environment in the box that meets the experimental needs.
Applications
Plant growth research, seed germination experiment, biological fostering, environment simulation test
Standards
Humidity uniformity meets national standards
Steps
1. Place the device in a working environment (temperature + 5~ 30 ° C) that meets the requirements, and connect the AC220V 50Hz power supply.
2. Open the box door and install or adjust the Shelf bracket as required.
3. Close the box door and set the required temperature, Humidity, Illumrination degree and time program through the microcomputer control panel.
4. After confirming that the parameters are set correctly, start the device and start running.
5. During the experiment, the real-time operation status can be observed through the panel.
6. After the experiment, turn off the power supply of the equipment and perform cleaning and maintenance in the box.
Notice
Equipment should be placed in a well-ventilated place with an Ambient Temperature between + 5 and 30 ° C.
Make sure to use an AC220V 50Hz power supply and ensure good grounding.
• When the equipment is running, do not open the door frequently to avoid affecting the internal environment Stability.
• Do not use corrosion cleaners when cleaning liners.
• Pay attention to the equipment alarm prompt, and check the over-temperature alarm system in time after starting-up.
• If you need to choose CO2 function, please confirm that the relevant accessories have been installed correctly and calibrated.
When not in use for a long time, disconnect the power supply and clean and protect the equipment.