Overview
The HZLB LRGD-350B low temperature light chamber is an intelligent Artificial climate box with a volume of 350L. The product is controlled by a microcomputer program, which can accurately simulate the temperature and Humidity changes during the day and night, and provide a sufficient and stable light environment. It is suitable for various experiments that require controlled growth conditions. Its working mode is continuous cycle, and it can operate stably at Ambient Temperature of + 5~ 30 ℃.
Features
1. Microcomputer program control Temperature, Humidity, Illumrination degree, can simulate day and night temperature Humidity changes or provide stable Illuminant.
2. 30-stage programs can be set, each lasting 1-99 hours, to meet the parameter requirements of different stages of plant growth.
3. Adopt brand Compressor and environmentally friendly refrigerant (R134a) to ensure long-term continuous, efficient and low energy consumption operation of the equipment.
4. Mirror stainless steel liner, four corners and half arc transition, Shelf bracket can be freely loaded and unloaded, easy to clean in the box.
5. Equipped with an independent temperature limit alarm system, the temperature limit is automatically interrupted to ensure the safety of the experiment.
6. Light intensity 0-12000LX, four-level adjustable, using two-sided vertical lighting mode.
7. Optional CO2 inlet and imported infrared CO2 Sensor controller to promote plant growth.
Principle
The incubator controls the Compressor, heater, humidifier and lighting components through a microcomputer program Control system. The system automatically adjusts the environment in the box according to the set temperature (-15~ 50 ° C), Humidity (50-95% RH) and Illumrination degree (0-12000LX, four-level adjustable) parameters, simulating natural or specific climate conditions, providing a controlled growth or experimental environment for samples. The independent temperature limit alarm system monitors the whole process to ensure safe operation.
Applications
Plant growth research, seed germination experiment, microbial fostering, tissue fostering, environment simulation test
Standards
Humidity uniformity meets national standards (+/- 5% RH~ +/- 7% RH)
Steps
1. Place the device in a working environment of + 5~ 30 ° C and connect the AC220V 50Hz power supply.
2. Through the microcomputer control panel, set the required temperature, Humidity and lighting program (up to 30 segments).
3. According to the experimental requirements, install or adjust the Shelf bracket in the box and place the experimental samples.
4. Start the device, the system will automatically run according to the set program, simulate day and night changes or maintain a constant environment.
5. During operation, real-time parameters can be monitored through the panel, and an independent alarm system provides security.
6. After the experiment, remove the sample, disconnect the power supply, and remove the Shelf if necessary to clean the box.
Notice
Equipment should be placed in a well-ventilated place with an Ambient Temperature of + 5~ 30 ° C.
• Please use the specified power supply (AC220V 50Hz) and ensure good grounding.
When cleaning the box, please take care to avoid sharp objects scratching the stainless steel liner.
• During operation, do not frequently open and close the box door, so as not to affect the environment Stability inside the box.
• If the CO2 system is selected, please follow the relevant instructions to connect and use the CO2 gas source and controller correctly.
• When the alarm system starts-up, please check and troubleshoot in time before resuming operation.