Overview
The HZLB LRGD-450B cryogenic light chamber is an intelligent artificial climate device that uses microcomputer program control to accurately simulate day and night temperature, Humidity and light changes, providing a stable environment for plant growth research. The device has a volume of 450L, uses a mirror stainless steel liner, and is equipped with a brand Compressor to support long-term continuous operation.
Features
1. Microcomputer program controls Temperature, Humidity, Illumrination degree, can simulate day and night changes or provide stable Illuminant.
2. 30-stage programs can be set, each lasting 1-99 hours, to meet the requirements of plant growth parameters at different stages.
3. Using brand Compressor and environmentally friendly refrigerant (R134a), efficient operation and low energy consumption.
4. Mirror stainless steel liner, four corners and a half arc transition, Shelf bracket can be freely loaded and unloaded, easy to clean.
5. Equipped with an independent temperature limit alarm system, overheating is automatically interrupted to ensure experimental safety.
6. Optional CO2 inlet and imported infrared CO2 controller to promote plant growth.
Principle
The incubator integrates the Compressor, humidification system and lighting components through a microcomputer control system to achieve precise setting and stable maintenance of temperature, Humidity and light intensity in the box. Its refrigeration system uses Air-Cooled technology to work in cycles to simulate the desired day and night environment or constant growth conditions.
Applications
Plant growth research, seed germination experiment, tissue fostering, ecological simulation
Standards
Humidity uniformity meets national standards
Steps
1. Place the device in a working environment of + 5~ 30 ° C and connect the AC220V 50Hz power supply.
2. Through the microcomputer control panel, set the required temperature, Humidity and lighting program (up to 30 segments).
3. Install or adjust the internal Shelf bracket as needed to place the experimental sample.
4. Start the device, the device will automatically run according to the set program, simulating environment changes.
5. After the experiment, turn off the equipment, disconnect the power supply, and clean the box.
Notice
Equipment should be placed at the required Ambient Temperature (+ 5~ 30 ℃).
● Power supply voltage AC220V 50Hz before operation.
● When cleaning the liner, pay attention to the safety of loading and unloading Shelf brackets.
● Pay attention to the Temperature range (-15~ 50 ℃) set by the device to avoid overuse.
If you choose a CO2 system, please follow the relevant instructions for operation and maintenance.