Overview
HZLB LRGD-1000A low temperature light chamber is an intelligent Artificial climate box with a volume of 1000L. It is controlled by a microcomputer program, which can accurately simulate the temperature and Humidity changes during the day and night, and provide a sufficient and stable light environment, suitable for scientific research and experiments such as plant growth.
Features
1. Microcomputer program control Temperature, Humidity, Illumrination degree, can simulate day and night temperature Humidity changes or provide stable Illuminant.
2. 30-stage programs can be set, each lasting 1-99 hours, to meet the parameter requirements of different stages of plant growth.
3. Adopt brand Compressor and environmentally friendly refrigerant (R134a) to ensure long-term continuous, efficient and low energy consumption operation of the equipment.
4. Mirror stainless steel liner, four corners and half arc transition, Shelf bracket can be freely loaded and unloaded, easy to clean in the box.
5. Equipped with an independent temperature limit alarm system, the temperature limit is automatically interrupted to ensure the safety of the experiment.
6. Optional CO2 inlet and imported infrared CO2 Sensor controller to promote plant growth.
Principle
The incubator integrates the Compressor, heater, humidifier and lighting system through a microcomputer Control system. The system precisely adjusts the temperature, Humidity and light intensity and time in the box according to the preset program, simulates the required day and night alternation or constant climate environment, and provides controlled growth conditions for biological foster.
Applications
Plant growth research, seed germination experiment, biological fostering, environment simulation test
Standards
Humidity uniformity meets national standards
Steps
1. Place the device in a working environment (temperature + 5~ 30 ° C) that meets the requirements, and connect the AC220V 50Hz power supply.
2. Through the microcomputer control panel, set the required temperature, Humidity, and lighting programs (up to 30 segments).
3. Place the sample to be fostered and close the box door.
4. Start the equipment and start a continuous cycle of operation.
5. During the experiment, the running status can be monitored through the panel, and the overheating of the equipment will automatically alarm and interrupt.
6. After the experiment, remove the sample, disconnect the power supply, and remove the Shelf if necessary to clean the box.
Notice
• Please ensure that the device operates at the specified Operating Ambient Temperature (+ 5~ 30 ° C).
• Power supply voltage AC220V 50Hz before use.
• The equipment is equipped with an independent temperature limit alarm system, please do not disable it at will, and pay attention to the alarm prompt.
• When cleaning the liner, the Shelf bracket can be loaded and unloaded, please pay attention to the safety of operation.
• The equipment is designed for continuous cycle work, please keep the surroundings well ventilated during long-term operation.
• Optional CO2 function requires separate controller and Sensor configuration.