Overview
The HZLB LRGD-1000B low temperature light chamber is an intelligent Artificial climate box with a volume of 1000L. It is controlled by a microcomputer program, which can accurately simulate the temperature and Humidity changes during the day and night, and provide a sufficient and stable lighting environment, suitable for various experiments that need to control growth conditions. The equipment adopts Air-Cooled refrigeration technology, has a wide Temperature range, stable operation and can work continuously.
Features
1. Microcomputer program controls Temperature, Humidity, Illumrination degree, can simulate day and night changes or provide stable Illuminant.
2. 30 programs can be set, each running for 1-99 hours, to meet the parameter requirements of different stages of plant growth.
3. The brand Compressor is used, and the refrigerant is R134a to ensure the continuous, efficient and low energy consumption operation of the equipment for a long time.
4. Mirror stainless steel liner, four corners and a half arc transition, Shelf bracket can be freely loaded and unloaded, easy to clean the box.
5. Equipped with an independent temperature limit alarm system, overheating is automatically interrupted to ensure experimental safety.
6. Optional CO2 inlet and imported infrared CO2 Sensor controller to promote plant growth.
Principle
The incubator coordinates the operation of the refrigeration/heating system, the humidification system and the lighting system according to the preset program instructions through the microcomputer Control system. The refrigeration system uses Air-Cooled technology and Compressor to achieve precise control of the temperature in the box; the humidification system adjusts Humidity; and the lighting system provides scalable light intensity through vertical Illuminants on both sides, thus creating an experimental temperature, Humidity and lighting environment in the box.
Applications
Plant growth research, seed germination test, biological fostering, environment simulation experiment
Standards
Humidity uniformity meets national standards
Steps
1. Place the device in a working environment (temperature + 5~ 30 ° C) that meets the requirements, and connect the AC220V 50Hz power supply.
2. Open the box door and install or adjust the Shelf bracket as required.
3. Close the box door and set the required temperature, Humidity, Illumrination degree and time program through the microcomputer control panel.
4. After confirming that the parameters are set correctly, start the device and start running.
5. During the experiment, the environment in the box can be monitored through the observation window or data recording function.
6. After the experiment, turn off the device according to the program and disconnect the power supply.
7. Carry out cleaning and maintenance in the box.
Notice
• Equipment should be placed in a well-ventilated place with Ambient Temperature + 5~ 30 ° C.
Make sure to use an AC220V 50Hz power supply and ground it reliably.
Please check the parameter settings carefully before running to avoid setting errors.
The equipment is equipped with an independent temperature limit alarm, but the operator still needs to conduct regular inspections to prevent accidents.
• When cleaning the liner, pay attention to safety and remove the Shelf bracket if necessary.
• If the CO2 system is optional, follow the relevant instructions for installation and operation.
The equipment is designed to work in a continuous cycle, but it is recommended to check it intermittently after a long period of operation.
• Non-professionals should not disassemble or repair the internal parts of the equipment.