Overview
HZLB LRGD-1500B low temperature light chamber is an intelligent Artificial climate box with a volume of 1500L. It is controlled by a microcomputer program, which can accurately simulate the temperature and Humidity changes of day and night, and provide a sufficient and stable light environment, suitable for plant growth and other research. The equipment uses a brand Compressor, which operates stably and consumes low energy.
Features
1. Microcomputer program controls Temperature, Humidity, Illumrination degree, can simulate day and night changes or provide stable Illuminant.
2. 30-stage programs can be set, each lasting 1-99 hours, to meet the parameter requirements of different stages of plant growth.
3. The brand Compressor is used, and the refrigerant is R134a to ensure the continuous and stable operation of the equipment for a long time, and the energy consumption is low.
4. The liner is made of mirror stainless steel, with four corners and a half arc transition, and the Shelf bracket can be freely loaded and unloaded, which is convenient for cleaning in the box.
5. Equipped with an independent temperature limit alarm system, the temperature exceeds the set limit and is automatically interrupted to ensure the safety of the experiment.
6. Can be equipped with CO2 inlet and imported infrared CO2 Sensor controller to promote plant growth.
Principle
The incubator integrates the Compressor, humidification system and lighting system through a microcomputer Control system to achieve precise control of the temperature, Humidity and illuminance in the box. The system can automatically cycle to change the environment parameters according to the preset multi-stage program to simulate natural or specific artificial climate conditions, providing a controlled growth environment for biological foster.
Applications
Plant growth research, seed germination test, biological fostering, environment simulation experiment
Standards
Humidity uniformity meets national standards
Steps
1. Place the device in a working environment of + 5~ 30 ° C and connect the AC220V 50Hz power supply.
2. Through the microcomputer control panel, set the required temperature, Humidity and lighting program (up to 30 segments).
3. According to the experimental requirements, install or adjust the Shelf bracket in the box.
4. Start the equipment, the system will automatically run according to the set program to simulate the required climate conditions.
5. During the experiment, real-time parameters can be monitored through the panel, and the equipment is equipped with an over-temperature automatic protection function.
6. After the experiment, turn off the equipment, disconnect the power supply, and remove the Shelf for cleaning in the box.
Notice
● Equipment should be placed in a place with an Ambient Temperature of + 5~ 30 ° C.
Make sure the power supply is AC220V 50Hz and is reliably grounded.
Please confirm that the program parameters are set correctly before running.
● When cleaning the liner, please pay attention to safety and remove the Shelf bracket for operation.
The equipment is equipped with an independent temperature limit alarm, but the experimenter still needs to conduct regular inspections to ensure safe operation.
If CO2 control function is required, additional corresponding components are required.