Please contact customer service
Using top LED cold Illuminant, the energy consumption is about 80% lower than that of ordinary Illuminant, and the lifespan is up to 50,000 hours. 30-stage program can be set, Temperature range 0-50 ℃, Humidity Control Range 50-95% RH, support horizontal circulation air and adjustable shelves to ensure uniform and stable experimental environment.
Category : Environmental Chamber
Brand : hzlb
SKU : NB025344
Service :The delivery and service By NBCLab.Com
HZLB LRG-450-LED Artificial climate box (LED Illuminant) is a 450L volume precision environment simulation equipment. It uses microcomputer program control, can accurately simulate day and night temperature, Humidity changes, and provide stable and adjustable light environment, suitable for plant growth, seed germination and other research and applications.
1. Microcomputer program controls Temperature, Humidity, Illumrination degree, can simulate day and night changes or provide stable Illuminant. 2. 30-stage programs can be set, each lasting 1-99 hours (optional), to meet the requirements of different growth stages. 3. Adopt brand Compressor and R134a environmentally friendly refrigerant to ensure long-term continuous, efficient and low energy consumption operation. 4. With anti-fog observation window and door lock, liner is mirror stainless steel, four corners and a half arc transition, Shelf bracket can be freely loaded and unloaded for easy cleaning. 5. Using overhead LED cold Illuminant (Color temperature 4000K), the beam of light does not produce heat, and extracts Light spectrum that is conducive to plant growth, Illuminant board size 420 * 480mm, 675 lamp beads per board. 6. LED Illuminant has the characteristics of miniaturization, planarization and strong designability, which can realize random arrangement of point formation and free combination of multi-color light. 7. LED Illuminant energy consumption is about 80% lower than that of ordinary Illuminant, combined with foam insulation technology, which significantly reduces the cost of use, and the warranty-free period of the whole machine is extended to two years. 8. LED Illuminants have a lifespan of more than 50,000 hours, high photoelectric conversion efficiency, and a service life of more than 16 times that of ordinary Illuminants (3000 hours). 9. LED Illuminant Response Time is nanosecond, integrated point array design to ensure uniform light coverage. 10. The light box can be easily replaced and can be used independently as an Illuminant board. When the temperature required by the foster is consistent with the environment, the temperature control can be turned off to achieve a dual-use box. 11. Top-mounted plane lighting ensures that the foster can fully and uniformly absorb the Illuminant and maintain the conformity of the experimental results. 12. Horizontal circulating air is used to ensure uniform temperature between layers. 13. Shelf height adjustable, high internal space, Illuminant height can be adjusted with crop growth. 14. Equipped with an independent temperature limit alarm system (optional), overheating automatically interrupts to ensure experimental safety. 15. It can record the changes of various parameters, and the data can be downloaded through a U disk; an optional RS485 interface can be connected to a computer to achieve simultaneous monitoring and data recording. 16. It can be equipped with a CO2 inlet and an imported infrared CO2 controller to promote plant growth. 17. Each layer can be equipped with LED Illuminants of different Colors (optional).
The device is precisely programmed to control the temperature, Humidity and light in the box through a microcomputer Control system. The refrigeration system (Compressor and R134a refrigerant) and the humidification system work together to regulate the environment in the box. The unique overhead LED point array Illuminant provides stable, uniform and efficient light, and its Light spectrum is optimized to facilitate plant growth. The horizontal circulation air system ensures uniform temperature and Humidity in all areas of the box. Users can set up multi-stage programs to simulate complex day and night environment changes or maintain constant growth conditions according to experimental needs.
Plant growth research, seed germination test, biological fostering, agricultural research, environment simulation experiment
The data did not mention specific compliance criteria
The information does not provide specific operation steps
* Ambient Temperature should be in the range of RT + 0~ 30 ℃. * Environmental humidity should be less than 85%, and no corrosion gas. * Equipment should be placed in a stable, well-ventilated position. * Please read the manual carefully before use to ensure that the Power supply voltage is AC 220V 50Hz. * Shelf mountable for easy operation when cleaning liner. * Optional functions (such as multi-segment program timing, temperature limit alarm, data recording interface, CO2 control, different layers of Color Illuminant) need to be confirmed and used according to the actual book configuration. When not in use for a long time, disconnect the power supply and do a good job of cleaning and maintenance.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.