Please contact customer service
Using overhead LED cold Illuminant, uniform light and no heat pRoduction, the lifespan is up to 50,000 hours. Supports 30-stage program control, 1-99 hours each, Temperature Fluctuation +/- 0.5 ℃, which can realize independent or combined operation of temperature and light.
Category : Incubator
Brand : hzlb
SKU : NB025348
Service :The delivery and service By NBCLab.Com
The HZLB LGZ-250-LED light chamber (top LED Illuminant) is a microcomputer programmed precision device for simulating the light and temperature environment required for plant growth. It has a 30-stage programming function, which flexibly simulates day and night temperature changes and provides a stable and sufficient Illuminant. The cabinet is equipped with a mirror stainless steel liner, an overhead flat LED cold Illuminant and a horizontal circulation system to ensure a uniform foster environment.
1. Microcomputer program control temperature and Illumrination degree, LCD liquid crystal display, can simulate day and night temperature changes. 2. 30-stage programs can be set, each lasting 1-99 hours, to meet the requirements of plant growth parameters at different stages. 3. Using brand Compressor and R134a refrigerant to ensure long-term continuous, efficient and low energy consumption operation. 4. With anti-fog observation window and door lock, mirror stainless steel liner four corners and half arc transition, Shelf bracket can be freely loaded and unloaded, easy to clean. 5. Using overhead LED Cold Illuminant (Color temperature 4000K), the beam of light does not produce heat, extracting Light spectrum that is conducive to plant growth, 675 lamp beads per board. 6. LED Illuminant has the characteristics of miniaturization, planarization and strong designability, which can realize the free arrangement of point formation and multi-color light. 7. LED energy consumption is extremely low, about 80% energy saving than ordinary Illuminant, combined with foam insulation technology to reduce the cost of use, and the warranty-free period of the whole machine is extended to two years. 8. Illuminant has a lifespan of more than 50,000 hours, high photoelectric conversion efficiency, and a service life of more than 16 times that of ordinary Illuminant (3000 hours). 9. LED Response Time is nanosecond, integrated point array Illuminant to ensure uniform light coverage. 10. The light box can be easily replaced and can be used independently as an Illuminant board to achieve dual-use (when the temperature control needs to be turned off). 11. Top-mounted planar illumination ensures that the foster can fully absorb the Illuminant and maintain the conformity of the experimental results. 12. Horizontal circulating air ensures uniform temperature across layers. 13.Adjustable shelf, high internal space, Illuminant height can be adjusted with crop growth. 14. It is equipped with an independent temperature limit alarm system (optional), which automatically interrupts when the temperature exceeds the limit to ensure the safety of the experiment. 15. Parameter changes can be recorded, and data can be downloaded and stored through a U disk; optional RS485 interface can be connected to a computer to synchronize monitoring or record data. 16. Can be equipped with CO2 air inlet and imported infrared CO2 controller (optional) to promote plant growth. 17. Each layer can be equipped with LED Illuminants of different Colors (optional).
The light chamber precisely adjusts the temperature and light parameters in the box through a microcomputer Control system. Temperature control is achieved by the Compressor refrigeration system and the heating system working together, and the horizontal circulating air ensures the uniform temperature in the box. The light is provided by the overhead LED Illuminant board, and the LED lamp beads emit a cold light of a specific Light spectrum to simulate the light conditions required for plant growth. User programmable setting of multiple different temperature and light combinations to simulate natural or specific environment growth cycles.
Plant fostering, seed germination, tissue fostering, microbial fostering, insect feeding, biological product preservation and other experimental research fields that require precise control of light and temperature
Not mentioned
1. Place the equipment in a stable, ventilated, non-corrosion gas environment, Ambient Temperature 0-30 ℃, Humidity < 85%. 2. Connect the 220V/50Hz power supply. 3. Set the required temperature, Illumrination degree and program parameters through the microcomputer control panel. 4. Place the items to be fostered on the adjustable shelf and adjust the shelf height as needed. 5. Close the box door and lock it, and start the device operation program. 6. The internal situation can be viewed through the observation window, and the data can be downloaded through the U disk during operation or after completion (if equipped with this function). 7. After the experiment, turn off the power and remove the items. 8. Shelf holder can be removed to clean liner when needed.
• Please ensure that the equipment works at the specified Ambient Temperature (0-30 ° C) and Humidity (< 85%), and there is no corrosion gas around. The equipment will generate noise (≤ 70dB), please place it in a suitable place. The observation window has anti-fog function, please use soft fabric when cleaning. • The liner is mirror stainless steel, avoid using sharp or corrosion cleaners when cleaning. • The Compressor is in Intermittent Operating Mode, which is a normal phenomenon. • If the temperature limit alarm system is selected, please do not turn off this function at will to ensure safety. • When cleaning the box or replacing the Illuminant, be sure to disconnect the power supply of the device. • Optional functions (such as CO2 control, RS485 interface, specific Color Illuminant) need to be clear when booking. The equipment exemption period is two years (based on the commitment to reduce the accident rate of the whole machine as stated in the data).
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.