Overview
HZLB 101-00SB electric thermostatic blast drying oven is a volume of 42L laboratory equipment, using stainless steel liner and microcomputer intelligent temperature control system, with accurate temperature control and air circulation heating function, suitable for Temperature uniformity requirements high drying, heating and other scenes.
Features
1. Microcomputer intelligent temperature control display, with PID self-tuning, automatic temperature warning, leakage protection, time setting functions, high temperature control accuracy.
2. Adopt wind circulation heating, control the air in the box through a microcomputer, simulate the natural environment, and make the heating more uniform.
3. Stainless steel studio, double door structure, the inner door is made of tempered Glass, which can still maintain long thermostatic after power failure, which is convenient for observation.
4. The shelf can be adjusted freely, and the gap can be adjusted reasonably according to the specifications of the stored items, making full use of the space.
Principle
Control system of the microcomputer, the air in the box is heated, and the air circulation system is used to make the hot air flow evenly in the studio, so as to realize the thermostatic drying or heating treatment of the goods. Its PID self-tuning function can accurately maintain the set temperature.
Applications
Seed germination experiment, laboratory drying, material heating
Steps
1. Turn on the power supply (220V +/- 22V, 50Hz +/- 0.5Hz).
2. Set the required temperature (RT + 5~ 300 ° C) and time (1~ 9999 minutes) through the microcomputer control panel.
3. Adjust the shelf position according to the stored items.
4. Put in the items to be processed and close the box door.
5. The equipment starts, starts heating and runs the air circulation.
6. After reaching the set time or temperature, the device may automatically stop or alarm to remove items.
Notice
* Equipment should work under the condition of no corrosion gas, Ambient Temperature RT + 0~ 35 ℃.
* Power supply voltage meets the requirements (220V +/- 22V, 50Hz +/- 0.5Hz).
* Do not open the door for a long time when the equipment is running, so as not to affect the Temperature uniformity and thermostatic effect.
When placing items, do not block the air duct to ensure even circulation of hot air.
The equipment has a leakage protection function, but it is still necessary to ensure good grounding and pay attention to electrical safety.
* Please disconnect the power supply when cleaning, wipe with a soft cloth, and avoid the use of corrosion cleaners.