Overview
GZP-350 light Chamber is a device for accurately simulating diurnal temperature and light changes. It is widely used in microbial tissue cell fostering, seed germination, seedling experiment, plant cultivation, insect and small animal feeding and other fields.
Features
1. Mirror stainless steel liner, four corners and a half arc transition, Shelf bracket can be freely loaded and unloaded, easy to clean in the box.
2. Double door structure, good insulation performance. The inner door is a fully tempered Glass door, which does not affect the temperature in the box when observed.
3, Microcomputer program control temperature, Illumrination degree, can simulate day and night temperature and Illumrination degree changes.
4, with over-temperature alarm system, beyond the set temperature that emits sound and light alarm and cut off the heating system to ensure safety.
5. Fluorine-free design and professional LED Illuminant lighting are used to effectively save energy and promote emission reduction.
6. Programmable lighting Chamber (S type) with 30 programmable temperature control instrument, up to 30 temperature changes can be set.
7. Artificial climate box integrates temperature, Humidity and Illumrination degree control, and the 30-segment programmable controller can simulate the natural climate as much as possible.
8, can be equipped with embedded printer or RS-485 Communication interface, real-time monitoring of the experimental process or record experimental data (optional).
Principle
Control system of the microcomputer program, the heating, cooling and LED Illuminant in the box are precisely regulated to simulate the set day and night temperature and Illumrination degree change Linear dispersion, so as to provide the required growth environment for the foster.
Applications
Microbial tissue cell fostering, seed germination, seedling experiment, plant cultivation, insect and small animal feeding
Steps
1. Place the device in a stable and well-ventilated position and connect the power supply.
2. Set the required temperature, Illumrination degree and time program (if applicable) through the microcomputer control panel.
3. Put the sample to be fostered on the shelf of the box and ensure that it is placed evenly.
4. Close the inner fully tempered Glass door and the outer door, and start the equipment operation program.
5. During operation, the inside of the box can be observed through the Glass door, or the data can be recorded through the optional Interface monitoring.
6. After the experiment, turn off the power of the equipment, remove the sample, and clean the box.
Notice
Equipment should be placed in a smooth, well-ventilated environment.
• Do not frequently open and close the box door, so as not to affect the internal temperature and light Stability.
• Note that the device Rated voltage is AC 220V 50Hz, please make sure the power supply matches.
• If the over-temperature alarm is triggered during operation, please check and troubleshoot in time.
• When cleaning the liner, disconnect the power first and wipe it with a soft cloth.
• Optional printer or Communication interface function, please follow the corresponding instructions.