Overview
JINGHONG GZP-450S program-controlled light Chamber is a device that integrates temperature and Illumrination degree control. It is widely used in microbial tissue cell fostering, seed germination, seedling test, plant cultivation and insect and small animal feeding. It can accurately simulate the temperature and light changes during the day and night.
Features
1. Mirror stainless steel liner, four corners and a half arc transition, Shelf bracket can be freely loaded and unloaded, easy to clean in the box.
2. Double door structure, good insulation performance. The inner door is a fully tempered Glass door, which does not affect the temperature in the box when observing the situation in the box.
3, Microcomputer program control temperature, Illumrination degree, can simulate day and night temperature and Illumrination degree changes.
4, with over-temperature alarm system, beyond the set temperature that emits sound and light alarm and cut off the heating system to ensure the safe operation of equipment.
5. Fluorine-free design, equipped with professional LED Illuminant lighting, effective, energy saving, promote emission reduction.
6. With a 30-stage programmable temperature controller, up to 30 temperature changes can be set.
7, Set temperature, Humidity, Illumrination degree control in one, can simulate the natural climate as much as possible.
Optional embedded printer or RS-485 Communication interface, real-time monitoring of the experimental process or record experimental data.
Principle
The device uses a microcomputer program controller to precisely adjust the heating, cooling and LED Illuminant systems in the box to achieve preset temperature and Illumrination degree change programs, thereby simulating the day and night temperature photoperiod changes in the natural environment.
Applications
Microbial tissue cell fostering, seed germination, seedling experiment, plant cultivation, insect and small animal feeding
Steps
1. Place the equipment in a stable and well-ventilated environment and connect the power supply.
2. Through the microcomputer program control panel, set the required temperature, Illumrination degree and time program segment.
3. Put the samples to be fostered or tested on the shelf of the box, and close the inner Glass door and the outer door.
4. Start the equipment operation program, and the equipment will automatically control the temperature and light changes according to the setting program.
5. During the experiment, the inside of the box can be observed through the Glass inner door, or the data can be monitored and recorded through the optional Interface.
6. After the experiment, turn off the power of the equipment, remove the sample, and perform necessary cleaning and maintenance.
Notice
Equipment should be placed in a stable, ventilated, away from heat sources and flammable and explosive environment.
• Do not frequently open and close the box door, so as not to affect the internal temperature and light Stability.
• When cleaning the liner, please disconnect the power first and wipe it with a soft cloth to avoid the use of corrosion cleaners.
• If the over-temperature alarm is triggered during operation, please check the set parameters and equipment operation status in time.
• Optional printer or Communication interface, please install and use according to the corresponding instructions.
• The equipment consumes a lot of Power, please ensure that the power supply line meets the requirements and avoid sharing sockets with Miscellaneous high-power appliances.