Please contact customer service
Made of high borosilicate Glass 3.3, with a temperature difference of 90 ° C, equipped with stepless speed regulation Stirrer, Speed range 50-500rpm, torque up to 70N-cm, and equipped with Vacuum Level Meter and temperature display unit.
Category : Reactor
Brand : GreatWall
SKU : NB026562
Service :The delivery and service By NBCLab.Com
GR-2 double-decked speed regulation Glass Reaction Kettle is a laboratory equipment produced by GREATWALL. The effective volume of the kettle body is 2L, and the jacket volume is 0.6L. It is made of high borosilicate Glass 3.3 material. Operating temperature range is wide (-80~ 200 ℃). It is suitable for stirring, reaction, distillation and other operations under normal or negative pressure conditions. The equipment integrates a Vacuum Level meter and a temperature display unit to facilitate real-time monitoring of the reaction status.
1. Four kettle body specifications of 1L, 2L, 3L and 5L are available. 2. Equipped with Vacuum Level Meter and Temperature Display Unit for easy process monitoring. 3. High Borosilicate Glass 3.3 material, with good heat resistance and Chemical Stability. 4. The mixing system adopts 70W stepless speed regulating motor, Speed range 50~ 500rpm, Max. Torque 70N-cm. 5. Equipped with a side discharge valve without liquid accumulation, the height of the discharge valve from the ground can be adjusted within the range of 100-210mm. 6. The key sealing parts are made of polytetrafluoroethylene, and the stirring shaft is stainless steel outsourcing tetrafluoroethylene, which is resistant to corrosion. 7. Standard constant pressure funnel (200ml) and condenser (condensing area 0.025 m2). 8. Adopt standard grinding port design (24 #, 19 #), easy to connect and universal.
The Reaction Kettle heats or chills down the material in the kettle by jacketing into a circulating heat conducting medium (such as hot water, ice water or oil bath). The stirring motor drives the Impeller (four-leaf propulsion) swirl/spin through stepless speed regulation to mix the material evenly. The system can operate under normal pressure or vacuum conditions. The pressure is monitored by the Vacuum Level meter and the temperature sensor monitors the material temperature to achieve a controlled reaction environment. Feeding can be carried out through the constant pressure funnel or liquid feeding port, and the product can be discharged through the side discharge valve at the bottom.
Chemical synthesis, drug development, materials science, biochemistry, teaching experiments
1. Check whether the Glass parts, seals and interfaces are in good condition and clean. 2. Install the Reaction Kettle firmly through the fixed frame. 3. Connect the jacket circulation pipeline and connect the heat conducting medium. 4. Add the reaction material through the feeding port or constant pressure funnel. 5. Install Impeller and ensure good sealing. 6. Connect the vacuum system (if necessary) and check the air tightness. 7. Turn on the power and set the required Rotation speed. 8. Start the circulating medium temperature control system and set the reaction temperature. 9. Monitor the reaction process with Vacuum Level Meter and Temperature Display Unit. 10. After the reaction, turn off the heating/chill down and stir. 11. Collect product through side discharge valve. 12. Clean and maintain equipment.
● Do not exceed the equipment calibration Operating temperature (-80~ 200 ℃) and jacket internal and external temperature difference (90 ℃) limit. The operating pressure must not exceed the specified range of normal or negative pressure to avoid overpressure operation. ● Mechanical Impact on Glass Kettle should be avoided during feeding and operation. Make sure that the sealing of each grinding port is good, especially before the vacuum operation. Before stirring starts, please confirm that the Impeller has been installed correctly and rotates without obstacles. ● When using corrosion materials, pay attention to check the corrosion resistance of sealing parts and stirring shafts. ● Please use a suitable cleaning agent when cleaning, and avoid using sharp tools to scrape the inner wall of Glass. ● The power supply of the equipment is 100-240V~, 50/60HZ, please ensure that the power supply matches. ● Regularly check the sealing abrasion and replace it in time.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.