$ 12402.00Ex works
Using French Taikang Compressor and multi-wing air supply circulation, Temperature Uniformity ≤ +/- 2 ℃, humidity deviation + 2-3% R.H, with 100 sets of program capacity and RS-232/485 communication function.
Category : High Low Temperature Test Chamber
Brand : ZKHS
SKU : NB026919
Service :The delivery and service By NBCLab.Com
GDJS-010B high and low temperature alternating damping heat test chamber is suitable for aerospace products, information electronic Instruments, materials, electrical, electronic products, various electronic components in high and low temperature or heat and humidity environment inspection of its performance indicators. The box is processed by numerical control machine tool, beautiful and easy to operate.
1. The inner tank of the box is made of imported stainless steel (SUS304) mirror plate, and the shell is sprayed with A3 steel plate. Appearance has good texture and high cleanliness. 2. The replenishment tank has automatic water shortage protection, which is convenient for the operator to replenish the water source. 3. Large observation window with lighting, embedded tempered Glass, clear observation of the situation in the box. 4. The humidification system piping is separated from the control circuit board to avoid water leakage and improve safety. 5. The piping circuit system of the waterway system adopts door opening, which is convenient for maintenance and repair. 6. The box body insulation adopts ultra-fine fiberglass insulation cotton to avoid energy loss. 7. The left side of the box is equipped with a 50mm diameter test hole for external test power or signal wires. 8. The temperature and humidity control instrument adopts a 7.0-inch large screen, which is easy to operate, easy to edit programs, and supports Chinese and English interfaces. 9. With a capacity of 100 sets of programs and 1000 stages of 999 cycles, each time is set to a maximum of 99 hours and 59 minutes. 10. The controller has a screen lock function to avoid human touch shutdown. 11. With RS-232 or RS-485 communication interface, you can design programs and monitor the test process on the computer. 12. With automatic calculation function, it corrects the temperature and humidity change conditions for accurate and stable control. 13. The refrigerator adopts the original French "Taikang" fully enclosed Compressor. 14. The refrigeration system is designed with a unit or binary cryogenic loop system. 15. The multi-wing blower is used for strong air circulation, and the temperature and humidity are evenly distributed. 16. The air circuit circulation design makes the temperature and humidity stabilize quickly at the moment of opening the door, and the heating, cooling, and humidification systems are independent, reducing test costs, increasing lifespan, and reducing failure rates.
The test chamber adopts the original French "Taikang" fully enclosed Compressor and unit or binary low temperature circuit system through the refrigeration system to realize temperature control; the humidification system adopts a built-in isolated all-stainless steel shallow surface evaporative humidifier to realize humidity control; the circulation system adopts a multi-wing blower to strongly supply air to ensure the uniform distribution of temperature and humidity in the test area. The controller automatically calculates and corrects the temperature and humidity changes to maintain accuracy and stability.
Aerospace Products, Information Electronic Instruments, Materials, Electrical, Electronic Products, Various Electronic Components
GB/T10592-2008、GB/T10586-2006、GB/T2423.1-2008、GB/T2423.2-2008、GB/T2423.3-2006、GB/T2423.4-2008、GJB150.3A-2009、GJB150.4A-2009
1. Turn on the power supply and select AC220V +/- 10% 50Hz or AC380V +/- 10% 50Hz three-phase five-wire power supply. 2. Open the control instrument and select the Chinese and English operation interface. 3. Edit the program and set the temperature and humidity parameters and time (maximum 99 hours and 59 minutes). 4. Start the test and monitor the real-time operation Linear dispersion diagram. 5. After the test is completed, the machine will automatically shut down or stop manually.
• Operating Environment Temperature should be 5 ℃~ 30 ℃, humidity ≤ 85% R.H. • Avoid touching the controller screen artificially to prevent unplanned downtime. • Regularly check the water level of the replenishment tank to ensure that the automatic protection function of water shortage is normal. • Pay attention to the door opening structure of the pipeline and circuit system of the waterway system during maintenance. • Pay attention to the sealing and protection of the external cable when using the test hole. • Equipment with leakage, short circuit, over temperature, water shortage, motor overheating, Compressor overvoltage, overload, overcurrent protection, need to regularly verify the safety function.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.