$ 8287.00Ex works
Using French Taikang fully enclosed Compressor, temperature and humidity control accuracy of +/- 0.1 ℃ and +/- 1% R.H., with 100 program capacity and RS-485 communication function, support long-term stable operation.
Category : High Low Temperature Test Chamber
Brand : ZKHS
SKU : NB026920
Service :The delivery and service By NBCLab.Com
ZKHS GDJS-100C high and low temperature alternating damping heat test chamber is suitable for aerospace products, information electronic Instruments, materials, electrical, electronic products, various electronic components in high and low temperature or heat and humidity environment inspection of its performance indicators. The equipment adopts advanced structural design and control system to ensure a stable and reliable test environment.
1. The box is processed and formed by numerical control machine tool, and the operation is simple without reaction handle. 2. The liner is imported stainless steel mirror plate, the shell A3 steel plate is sprayed with plastic, and the appearance and texture are good. 3. The replenishment tank has automatic protection for water shortage, which is convenient for water replenishment. 4. Large observation window with lighting, embedded tempered Glass clear observation. 5. The humidification system piping is separated from the control circuit board to enhance safety. 6. Waterways and circuit systems are door-opened for easy maintenance and repair. 7. Insulation adopts ultra-fine fiberglass insulation cotton to reduce energy loss. 8. The left side of the box is equipped with a test hole for external test lines. 9. The controller adopts a 7.0-inch large screen, with optional Chinese and English interfaces, and supports 100 sets of programs and 1000 cycles. 10. With RS-232 or RS-485 communication interface, the automatic calculation function precisely controls the temperature and humidity. 11. The refrigerator adopts the original French Taikang fully enclosed Compressor, and the air circuit circulation design distributes temperature and humidity evenly. 12. Multiple safety protections include leakage, short circuit, over-temperature, water shortage, etc.
The temperature and humidity parameters of the test chamber are set by a programmable controller. The refrigeration system adopts a unit or binary low temperature circuit design, and cooperates with a multi-wing blower to circulate air to ensure uniform temperature and humidity in the test area. The humidification and dehumidification systems work independently, and the heating system adopts a nickel-chromium alloy electric heater to achieve rapid lifting and High Accuracy control.
Aerospace Products, Information Electronic Instruments, Materials, Electrical, Electronic Products, Various Electronic Components
GB/T10592-2008、GB/T10586-2006、GB/T2423.1-2008、GB/T2423.2-2008、GB/T2423.3-2006、GB/T2423.4-2008、GJB150.3A-2009、GJB150.4A-2009
Connect the power supply to ensure that the voltage meets the requirements of AC220V +/- 10% or AC380V +/- 10%. 2. Open the device and select the Chinese and English interface through the 7.0-inch Touchscreen controller. 3. Set the temperature and humidity parameters, and use the 100-program function to edit the test steps. 4. Place the test sample on the test rack and close the box door to ensure sealing. 5. Start the test and monitor the real-time operation Linear dispersion diagram. 6. After the test is completed, turn off the device and remove the sample.
• Operating Environment Temperature should be 5 ° C to 30 ° C, humidity should not exceed 85% R.H. • Ensure that the water source of the replenishment tank is sufficient to avoid protection downtime due to water shortage. • Pay attention to the opening of the waterway and circuit system during maintenance to avoid damage. • Do not touch the controller at will during the test to prevent misoperation and shutdown. • Regularly check safety protection devices, such as leakage, overheating, etc., to ensure normal operation. • Use the test hole on the left side of the box when connecting the external test cable, and pay attention to the cable specifications.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.