$ 9076.00Ex works
Inner Chamber dimensions 800 * 1000 * 1000mm, temperature range -20~ 150 ℃, humidity range 30~ 98% R.H., using French Taikang Compressor and multi-wing air supply circulation, uniform temperature and humidity distribution, high control accuracy.
Category : Temperature Humidity Chamber
Brand : ZKHS
SKU : NB026962
Service :The delivery and service By NBCLab.Com
GDS-800B high and low temperature damping heat test chamber is produced by ZKHS, suitable for aerospace products, information electronic Instruments, materials, electrical, electronic products and various electronic components in high and low temperature or heat and humidity environment inspection of its performance indicators. Inner chamber dimensions of the device are 800 * 1000 * 1000mm, Temperature range -20~ 150 ℃, Humidity Control Range 30~ 98% R.H., with precise temperature and humidity control and stable performance.
1. The box is processed by numerical control machine tool, which is beautiful and easy to operate 2. The liner adopts imported stainless steel (SUS304) mirror plate, and the shell A3 steel plate is sprayed with plastic. Appearance and texture are good 3. The replenishment tank has an automatic protection function for water shortage 4. Large observation window with lighting for clear observation of the situation in the box 5. The humidification system piping is separated from the control circuit board to improve safety 6. The pipeline circuit system of the water system adopts door opening, which is convenient for maintenance and repair 7. The box body insulation adopts ultra-fine fiberglass insulation cotton to avoid energy loss 8. The left side of the box is equipped with a 50mm diameter test hole, which can be used for external test lines 9. The temperature and humidity control instrument adopts a 7.0-inch large screen, which is easy to operate and easy to edit programs 10. With 100 sets of programs and 1000 segments of 999 cycle steps capacity 11. The controller has a screen lock function to avoid accidental touch and shutdown 12. With RS-232 or RS-485 communication interface, it supports computer remote control 13. With automatic calculation function, accurate and stable temperature and humidity control 14. The refrigerator adopts the original French "Taikang" fully enclosed Compressor 15. Multi-wing blower is used for strong air circulation, with uniform temperature and humidity distribution 16. Reasonable design of air circuit circulation, fast temperature and humidity stabilization time 17. The heating, cooling, and humidification systems are completely independent, effectively reducing testing costs
The equipment is heated by a fully independent system of nickel-chromium alloy electric heating heater, and the original French "Taikang" fully enclosed Air-Cooled compression refrigeration method is used to achieve cooling. The humidification system adopts a built-in isolated all-stainless steel shallow surface evaporative humidifier, and the dehumidification system adopts an evaporator coil dewpoint temperature laminar contact dehumidification method. Powerful air supply circulation is realized through a temperature-resistant and low-noise air-conditioning motor and a multi-blade centrifugal wind turbine to ensure uniform distribution of temperature and humidity in the test area. The controller has an automatic calculation function, which can correct the temperature and humidity change conditions in real time to achieve precise and stable control.
Aerospace Products, Information Electronic Instruments, Materials, Electrical, Electronic Products, Various Electronic Components
GB/T10592-2008、GB/T10586-2006、GB/T2423.1-2008、GB/T2423.2-2008、GB/T2423.3-2006、GB/T2423.4-2008、GJB150.3A-2009、GJB150.4A-2009
1. Turn on the power supply, select AC220V +/- 10% 50Hz or AC380V +/- 10% 50Hz three-phase five-wire power supply 2. Set temperature and humidity parameters and test time through 7.0 inch Touchscreen 3. Select or edit the test program, you can set up to 100 sets of programs, 1000 segments, 999 loops 4. After confirming the parameters, start the device and start the temperature and humidity test 5. Monitor the situation in the box in real time through the observation window 6. After the test is completed, the device automatically stops and the test sample is taken out
• Equipment Ambient Temperature should be within the range of 5~ 30 ℃ • Working environment humidity should be ≤ 85% R.H • Check the water level of the replenishment tank before use to ensure that the water source is sufficient • Regularly check whether the safety protection device is normal • Power should be turned off during maintenance • The test hole should be closed in time after use • Avoid opening doors frequently when the equipment is running • Power should be cut off when not in use for a long time
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.