$ 12248.00Ex works
Adopt stainless steel mirror liner and ultra-fine fiberglass insulation, Temperature Uniformity ≤ 2 ℃, humidity deviation + 2-3% R.H., with 100 sets of program storage and automatic calculation functions to improve test accuracy and efficiency.
Category : Temperature Humidity Chamber
Brand : ZKHS
SKU : NB026973
Service :The delivery and service By NBCLab.Com
GDS-010D high and low temperature damping heat test chamber is produced by ZKHS, which is suitable for aerospace products, information electronic Instruments, materials, electrical and electronic products and various electronic components in high and low temperature or heat and humidity environment inspection performance indicators. The box body is processed and formed by numerical control machine tool, which is easy to operate. The liner is imported stainless steel mirror plate, and the shell is A3 steel plate spray.
1. The box structure is sturdy and beautiful, with no reaction handle, easy to operate 2.The liner is imported stainless steel (SUS304) mirror plate, and the shell A3 steel plate is sprayed with high cleanliness 3. The replenishment tank has automatic protection for water shortage, which is convenient for water source replenishment 4. Large observation window with lighting, embedded tempered Glass, clear observation 5. The humidification system piping is separated from the control circuit board to improve safety 6. The pipeline circuit of the waterway system adopts door opening, which is convenient for maintenance and repair 7. The box body insulation adopts ultra-fine fiberglass insulation cotton to reduce energy loss 8. The left side of the box is equipped with a 50mm diameter test hole to support an external test line 9. The temperature and humidity control instrument has a 7.0-inch large screen, simple operation, and supports Chinese and English interfaces 10. With 100 sets of programs and 1000 segments of 999 cycle step capacity, each segment is set to a maximum of 99 hours and 59 minutes 11. Control the screen lock function of the appliance to prevent accidental touch and shutdown 12. Supports RS-232 or RS-485 communication, allowing for computer programming and monitoring 13. With automatic calculation function, accurate and stable control of temperature and humidity 14. The refrigerator adopts the original French "Taikang" fully enclosed Compressor 15. The refrigeration system adopts a unit or binary cryogenic circuit design 16. Multi-wing blower with strong circulation, uniform temperature and humidity distribution 17. The air circuit circulation design makes the temperature and humidity stabilize quickly, and the system independently reduces the failure rate
The test chamber realizes temperature control through a fully independent system: the heating system adopts a nickel-chromium alloy electric heating heater to heat up; the refrigeration system adopts the original French "Taikang" fully enclosed Air-Cooled Compressor for refrigeration; the humidification system adopts a built-in isolated all-stainless steel shallow surface evaporative humidifier to increase humidity; the dehumidification system adopts the evaporator coil dewpoint temperature laminar contact method to reduce humidity. The multi-wing blower strongly circulates the air to ensure the uniform distribution of temperature and humidity in the test area, and the controller automatically calculates and corrects the temperature and humidity changes to achieve precise and stable control.
Aerospace Products, Information Electronic Instruments, Materials, Electrical and Electronic Products, Various Electronic Components
GB/T10592-2008、GB/T10586-2006、GB/T2423.1-2008、GB/T2423.2-2008、GB/T2423.3-2006、GB/T2423.4-2008、GJB150.3A-2009、GJB150.4A-2009
1. Connect the power supply and ensure that the voltage is AC220V +/- 10% 50Hz or AC380V +/- 10% 50Hz three-phase five-wire system 2. Check the water level of the replenishment tank and replenish the water source if necessary 3. Set the temperature and humidity program through the 7.0-inch Touchscreen controller, and you can choose the Chinese and English interface 4. Use the test hole to connect an external power cable or signal cable 5. Start the equipment and monitor the real-time operation Linear dispersion diagram 6. After the test is completed, turn off the device and disconnect the power supply
• Operating Environment Temperature should be in the range of 5 ℃~ 30 ℃, humidity ≤ 85% R.H • Avoid running in a water shortage state to prevent automatic protection from triggering • Do not touch the controller screen at will during operation to prevent accidental touch and stop • Regularly maintain waterways and electrical systems to ensure safe operation • Pay attention to safety protection functions, including leakage, short circuit, over temperature, water shortage, motor overheating, Compressor overvoltage, overload, overcurrent protection
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.