Overview
WDCJ-500A high and low temperature impact test chamber is produced by ZKHS and is suitable for safety performance test, reliability test and product screening test of electronic components. Through this equipment test, product reliability can be improved and quality control can be implemented.
Features
1. Computer control, self-developed software, friendly operation interface, intuitive monitoring
2. Hold function allows temporary modification of parameters during program operation
3. The cold box and hot box are independently controlled, and the box door is independent, realizing three uses in one box
4. The box door is interlocked with the circulating fan and basket drive to ensure safe operation
5. The top of the box is equipped with a standard lead hole tube, which is convenient for introducing Sensor wires and detection cables
6. The conversion time between the low temperature zone and the high temperature zone is ≤ 15 seconds, and the temperature recovery time is ≤ 5 minutes
7. Adopt French Taikang fully enclosed Air-Cooled cascade compression refrigeration and German Copeland semi-enclosed Water-Cooled Compressor unit
8. Equipped with temperature-resistant and low-noise air-conditioning motors and multi-blade centrifugal wind turbine circulation system
Principle
The equipment automatically switches between cooling, heating and basket transfer through a computer control system to achieve high and low temperature Impact testing. Samples are quickly switched between low temperature and high temperature regions, and the temperature recovery is rapid to ensure test efficiency.
Applications
Electronic components safety performance test, reliability test, product screening test
Standards
GJB150.3A, GJB150.4A, GJB150.5A-2009 high and low temperature impact test standards
Steps
1. Set time parameters through 7.0 inch Touchscreen controller
2. Select the switching mode of cooling, heating and basket transfer
3. Set the test time (adjustable range~ 9999 M, H)
Step 4 Start the autorun
5. If necessary, the operating parameters can be temporarily modified by maintaining the function
Notice
• When the box door is opened, the circulating fan and basket drive power supply will be automatically cut off, please do not force the operation
• Temperature recovery time is affected by chilled down water temperature, exposure temperature difference, thermostatic time and sample weight
• power requirements AC380V +/- 10% 50Hz three-phase five-wire system
• The maximum load-bearing capacity in the sample area is 40kg, please do not overload it.