Overview
WDCJ-162B high and low temperature impact test box is produced by ZKHS, which is suitable for safety performance test, reliability test and product screening test of electronic components. The equipment can effectively improve product reliability and achieve quality control through high and low temperature Impact test. It adopts computer control system and self-developed software, and has an intuitive operation interface.
Features
1. Adopt computer control, equipped with self-developed software, and the operation interface is intuitive and simple
2. The cold box and hot box are independently controlled, and the box doors are independent of each other to achieve three uses in one box
3. The box door is interlocked with the circulating fan and the blue lifting drive to ensure safe operation
4. The top of the box is equipped with a standard lead hole tube, which is convenient for introducing Sensor wires and detection cables
5. Low temperature zone, high temperature zone conversion time ≤ 15 seconds, temperature recovery time ≤ 5 minutes
6. Equipped with 7.0 inch Touchscreen controller, accuracy range +/- 0.1 ℃
7. Adopt French Taikang fully enclosed Air-Cooled cascade compression refrigeration and German Copeland semi-enclosed Water-Cooled Compressor unit
8. Adopt temperature-resistant and low-noise air-conditioning motor and multi-blade centrifugal wind turbine circulation system
Principle
The test chamber realizes high and low temperature Impact test by computer control system, and adopts the design of independent control of cold box and hot box. During the test process, the equipment automatically switches between cooling, heating and blue lifting transfer, and the sample quickly switches between the low temperature zone and the high temperature zone. The conversion time does not exceed 15 seconds, and the temperature recovery time does not exceed 5 minutes.
Applications
Electronic components safety performance test, reliability test, product screening test
Standards
GJB150.3A, GJB150.4A, GJB150.5A-2009 high and low temperature impact test standards
Steps
1. Set time parameters through 7.0 inch Touchscreen controller
2. Set the cooling, heating, and bluing transfer switching program
3. Use the hold function to maintain the current running program state
4. Temporary change of program block value
5. Equipment is automatically tested according to the set value
Notice
• When the box door is opened, the power supply of the circulating fan and the blue drive will be automatically cut off to ensure safe operation
• Temperature recovery time is related to chilled down water temperature, exposure temperature difference, thermostatic time, sample weight
• power requirements AC380V +/- 10% 50Hz three-phase five-wire system
• The load-bearing capacity of the sample area is 20kg, please do not overload it.