Overview
The JINGQI DZF-6051 Vacuum oven is a device designed with a cuboid studio with a semi-circular arc at the four corners, which effectively improves the volume utilization rate. The equipment is equipped with a tempered bulletproof double-decked Glass door, which is convenient for observing the situation in the studio, and adopts a microcomputer intelligent digital temperature control system to ensure accurate and reliable temperature control.
Features
1. Cuboid studio, the four corners are semi-circular arcs, and the effective volume utilization rate is large.
2. Tempered, bulletproof double-decked Glass door, observation of indoor objects at a glance.
3. The box door is closed and elastic and adjustable, and the silicone rubber door sealing ring is integrally formed to ensure a high Vacuum Level in the box.
4. Microcomputer intelligent digital display temperature control, accurate and reliable temperature control.
5. The studio uses cold-rolled sheet to ensure the durability of the product.
6. Model DZF-6051 has the characteristics of microcomputer intelligent digital display, tempered Glass door, and cold-rolled liner.
Principle
The Vacuum oven extracts the air in the working room through the vacuum system, reduces the air pressure, thereby reducing the boiling point of the water, so that the material can be dried quickly at a lower temperature. At the same time, the microcomputer intelligent temperature control system precisely controls the heating temperature to ensure the Stability and uniformity of the drying process.
Applications
Electronic component drying, Chemical material dehydrating, Pharmaceutical Sample Handling, Laboratory Research, Food Industry Pretreatment
Standards
The data did not mention specific compliance criteria
Steps
1. Put the items to be dried on the shelf in the studio.
2. Close the door and adjust the tightness of the closure to ensure good sealing.
3. Turn on the power supply (~ 220V 50Hz) and set the required temperature parameters (Temperature range RT + 50~ 250 ℃).
4. Start the device, and the microcomputer intelligent temperature control system starts to work.
5. According to the process requirements, the vacuum system (Vacuum Level ≤ 133Pa) can be started for vacuum drying.
6. After drying is completed, turn off the heating and vacuum system. After the temperature in the box drops to a safe range, open the box door and take out the items.
Notice
• Equipment Ambient Temperature should be within the range of 5~ 40 ℃.
• Power supply voltage is~ 220V 50Hz and check if the ground is good.
• Check whether the sealing ring of the box door is in good condition before operation to ensure the Vacuum Level.
• Do not open the door frequently during drying to avoid affecting Vacuum Level and Temperature Stability.
When taking out high-temperature items, it is necessary to take good protection to avoid burns.
• Regularly clean the studio and keep the equipment clean.
• Non-professional personnel should not disassemble or repair the equipment.