Overview
SH-2000K Digital Display Pull-Pull Force Gauge is a small multi-functional High Accuracy Push-pull load test instrument produced by SUNDOO. It is suitable for push-pull load test, plug-in force test and failure test of various products. It has the characteristics of high digital Display resolution and convenient use. It is a new generation of effective high Accuracy push-pull force test instrument.
Features
Have software copyright (copyright number: 2004SR07474) and design patent (patent number: ZL20061007 2362.7).
2. The peak holding time can be freely set within 1 to 10 seconds.
3. The upper and lower deviation values can be set freely, and it has the functions of red and green indicator lights and buzzer automatic sound and light alarm.
4. With 10 sets of test value memory and average calculation functions.
5. Three units of N, kgf, and lbf can be automatically converted.
The shutdown time can be set freely within 1 to 60 minutes.
7. Linear dispersion can be viewed in real time through the test software, or the stored data can be imported into the computer for analysis, printing and other processing.
Principle
The Force Gauge uses an external hub-and-spoke Sensor. When the push and pull force is applied, the Sensor converts the mechanical signal into an electrical signal, and the force value is accurately displayed on the digital display screen after being processed by the internal circuit. Measurement range is 10%~ 100% FS, and data collection and analysis can be carried out by software.
Applications
Applicable to push-pull load testing, insertion force testing, and failure testing of various products
Standards
Indication Error : +/- 1%
Steps
1. Charge the device (Charging time is about 4 hours).
2. Start the machine and select the unit (N, KGF, LBF) according to the test requirements.
3. Set the peak holding time, upper and lower limit alarm values, and automatic shutdown time.
4. Conduct the test, and the device will display the force value in real time and maintain the peak value.
5. Test data can be stored (up to 10 groups) and averaged.
6. Connect the device to the computer through a cable, and use the supporting software to view real-time Linear dispersion or export data for further analysis.
Notice
* Measurement range is 10%~ 100% FS, do not use over range.
Please ensure that the battery is fully charged before use (the battery pack is 8.4V nickel-metal hydride battery, the charger input AC 200V 50Hz, the output DC 12V 300mA).
The battery can be used for about 40 hours after being fully charged. Please shut down when not in use for a long time to extend the standby time (about 3 months).
* Device weight is 14.2kg, please pay attention to safety when moving and operating.
* Please use the original charger for charging to ensure Battery life (≥ 300 cycles).