Overview
BOZHEN GD/HS4050 high and low temperature constant damping heat test chamber is a test equipment used to simulate high and low temperature and humidity environment, suitable for product adaptability testing in the fields of electronics and electricians, home appliances, automobiles, Instruments and other fields. The equipment adopts high-quality components, with stable temperature control performance and accurate humidity adjustment ability.
Features
1. The main components are imported parts with excellent performance, beautiful Appearance and good reliability.
2. With a wide temperature control range, it can meet the various needs of users.
3. Adopt unique equilibrate temperature control method, with stable equilibrate heating capacity, High Accuracy and High Stability Temperature Control.
4. The temperature is displayed digitally, making it intuitive and easy to read, accurate and convenient.
5. By adjusting the temperature error value, more accurate test conditions can be met.
6. The box is equipped with a large observation window, allowing the test status of the test sample to be observed at any time.
7. In the refrigeration system, the condensation method is Air-Cooled.
Principle
The test chamber achieves High Accuracy temperature control by equilibrating temperature control, combined with a humidity control system to simulate a constant heating and humidity environment. The refrigeration system adopts air-cooled condensation to ensure stable operation of the equipment and meet various environmental testing needs.
Applications
Electronics and electricians, household appliances, automobiles, Instruments, electronic chemicals, spare parts, raw materials and coatings, platings
Steps
Connect the device to a 380V/50HZ power supply.
2. Set the required temperature range (-40 ℃~ + 100 ℃) and humidity range (30~ 98% R. H).
3. Adjust the temperature error value through the digital display interface to ensure accurate test conditions.
4. Start the device and observe the sample status through a large observation window.
5. Monitor Temperature Fluctuation, Uniformity and Humidity deviation to ensure that the test meets the requirements.
Notice
• Power frequency is 380V/50HZ to avoid equipment failure due to voltage mismatch.
• Check the temperature setting before operation to prevent exceeding the Temperature range (-40~ 100 ℃).
• Maintain the refrigeration system regularly to ensure good air cooling and condensation effect.
• Use the observation window when observing the sample to avoid frequent door opening affecting the test stability.
• Pay attention to the range of humidity deviation, and control the accuracy separately under high humidity (above 75% R.H.) and low humidity (below 75% R.H.) conditions.