Please contact customer service
Using mainstream 8-bit micro-control technology, Fast Response and High Measurement accuracy. With IP65 Protection Rating, high-strength ABS material, two-level triple alarm (sound, light, vibration), Continuous Operating Time can reach more than 10 hours.
Category : Gas Detector
Brand : Bosean
SKU : NB028071
Service :The delivery and service By NBCLab.Com
BH-90A-CL2 is a Portable single Gas detector produced by BOSEAN brand, specially designed to detect chlorine (CL2). The instrument adopts mainstream 8-bit micro-control technology, with the characteristics of fast Response speed, high Measurement accuracy, Stability and Repeatability. The fuselage is compact, easy to operate, and has IP65 protection level of high waterproof performance, which can adapt to harsh working environments. Using high-strength ABS material, equipped with sound, light and vibration three-level alarm functions, safe and reliable, and high and low alarm values can be set. Built-in 3.7V rechargeable lithium battery, long battery life.
1. Adopt Industrial Sensor to Ensure Reliability. 2. The mainstream 8-bit micro-control technology is applied, and the performance is stable. 3. The fuselage is compact, and the operation is simple and convenient. 4. With IP65 protection level, it is highly waterproof. 5. Fast Response and High Sensitivity. 6. Long standby time, up to 10 hours of continuous operation. 7. Equipped with two-level triple alarm (sound, light, vibration), it is not easy to ignore. 8. High and low alarm values can be set as required. 9. Supports more than 30 types of Sensors, and can be flexibly configured or customized according to customer needs Gas detection type.
The Portable Gas detector uses the diffusion Sampling method, and the target gas enters the instrument through natural diffusion. The instrument has a special sensor for chlorine (CL2). When the gas comes into contact with the Sensor, the corresponding electrochemistry or physical signal changes will be generated. The signal is collected and processed by the microcontroller (MCU) inside the instrument. After calculation by the algorithm, the gas concentration value is displayed on the 1.77 inch high definition screen in real time. When the detection concentration exceeds the preset high or low alarm point, the instrument will immediately trigger sound, light and vibration alarms.
Chemical industry, petroleum and petrochemical, sewage treatment, environment monitoring, metallurgy and smelting, municipal pipe network, emergency rescue, laboratory, confined space operation
GB3836.1-2010、GB3836.4-2010、GB15322.3-2003、JJG693-2011、JJG365-2008、JJG695-2003、JJG915-2008
1. Power on: Press the power button for a long time to start the instrument and wait for the self-test to complete. 2. Calibrate: According to the service cycle or requirements, use standard gas for zero point and range calibrating (please refer to the manual for specific calibrating steps). 3. Settings: According to needs, enter the menu through the instrument button to set the high and low alarm values. 4. Detection: Carry the instrument to the environment to be tested, ensure that the Sensor part is exposed to the air, and wait for the reading to be stable. 5. Reading: Observe the real-time gas concentration value displayed on the screen. 6. Alarm Response: When the instrument emits sound, light and vibration alarm, take corresponding safety measures immediately. 7. Data viewing: The stored alarm records can be viewed through the instrument menu (support 1000 sets). 8. Shutdown: Long press the power button to turn off the instrument, or automatically enter sleep mode when not in use. 9. Charging: When the power is insufficient, use the matching charger to charge the instrument, and the Charging time is less than 5 hours.
• It is recommended to calibrate the instrument before it is used for the first time or after it has been idle for a long time. • Do not use under conditions exceeding the working Ambient Temperature (-20~ 50 ℃) and Humidity (0~ 95% RH non-condensation). • Avoid severe impact or drop of the instrument to prevent damage to the Sensor and internal components. It is forbidden to use it in an environment containing strong corrosion gas for a long time to avoid damage to the Sensor. When calling the police, evacuate to a safe area immediately and identify the cause. • Please use the original charger to charge and ensure a safe charging environment. • Sensors have a lifespan of about 2 years and should be replaced when they expire or their performance decreases. • The instrument is designed to be explosion-proof (Exib IIB T3 Gb), but should still be avoided in hazardous locations beyond the Explosion-proof level. • Do not disassemble or modify the instrument yourself. • Regularly check whether the Appearance and function of the instrument are normal.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.